Augmented reality-navigated pedicle screw placement: a cadaveric pilot study


Spirig, José Miguel; Roner, Simon; Liebmann, Florentin; Fürnstahl, Philipp; Farshad, Mazda (2021). Augmented reality-navigated pedicle screw placement: a cadaveric pilot study. European Spine Journal, 30(12):3731-3737.

Abstract

PURPOSE

Augmented reality (AR) is an emerging technology with great potential for surgical navigation through its ability to provide 3D holographic projection of otherwise hidden anatomical information. This pilot cadaver study investigated the feasibility and accuracy of one of the first holographic navigation techniques for lumbar pedicle screw placement.

METHODS

Lumbar computer tomography scans (CT) of two cadaver specimens and their reconstructed 3D models were used for pedicle screw trajectory planning. Planned trajectories and 3D models were subsequently uploaded to an AR head-mounted device. Randomly, k-wires were placed either into the left or the right pedicle of a vertebra (L1-5) with or without AR-navigation (by holographic projection of the planned trajectory). CT-scans were subsequently performed to assess accuracy of both techniques.

RESULTS

A total of 18 k-wires could be placed (8 navigated, 10 free hand) by two experienced spine surgeons. In two vertebrae, the AR-navigation was aborted because the registration of the preoperative plan with the intraoperative anatomy was imprecise due to a technical failure. The average differences of the screw entry points between planning and execution were 4.74 ± 2.37 mm in the freehand technique and 5.99 ± 3.60 mm in the AR-navigated technique (p = 0.39). The average deviation from the planned trajectories was 11.21° ± 7.64° in the freehand technique and 5.88° ± 3.69° in the AR-navigated technique (p = 0.09).

CONCLUSION

This pilot study demonstrates improved angular precision in one of the first AR-navigated pedicle screw placement studies worldwide. Technical shortcomings need to be eliminated before potential clinical applications.

Abstract

PURPOSE

Augmented reality (AR) is an emerging technology with great potential for surgical navigation through its ability to provide 3D holographic projection of otherwise hidden anatomical information. This pilot cadaver study investigated the feasibility and accuracy of one of the first holographic navigation techniques for lumbar pedicle screw placement.

METHODS

Lumbar computer tomography scans (CT) of two cadaver specimens and their reconstructed 3D models were used for pedicle screw trajectory planning. Planned trajectories and 3D models were subsequently uploaded to an AR head-mounted device. Randomly, k-wires were placed either into the left or the right pedicle of a vertebra (L1-5) with or without AR-navigation (by holographic projection of the planned trajectory). CT-scans were subsequently performed to assess accuracy of both techniques.

RESULTS

A total of 18 k-wires could be placed (8 navigated, 10 free hand) by two experienced spine surgeons. In two vertebrae, the AR-navigation was aborted because the registration of the preoperative plan with the intraoperative anatomy was imprecise due to a technical failure. The average differences of the screw entry points between planning and execution were 4.74 ± 2.37 mm in the freehand technique and 5.99 ± 3.60 mm in the AR-navigated technique (p = 0.39). The average deviation from the planned trajectories was 11.21° ± 7.64° in the freehand technique and 5.88° ± 3.69° in the AR-navigated technique (p = 0.09).

CONCLUSION

This pilot study demonstrates improved angular precision in one of the first AR-navigated pedicle screw placement studies worldwide. Technical shortcomings need to be eliminated before potential clinical applications.

Statistics

Citations

Dimensions.ai Metrics
4 citations in Web of Science®
3 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Surgery
Health Sciences > Orthopedics and Sports Medicine
Language:English
Date:4 August 2021
Deposited On:17 Jan 2022 13:50
Last Modified:18 Jan 2022 21:01
Publisher:Springer
ISSN:0940-6719
OA Status:Closed
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1007/s00586-021-06950-w
PubMed ID:34350487
Full text not available from this repository.