Navigation auf zora.uzh.ch

Search ZORA

ZORA (Zurich Open Repository and Archive)

Ex vivo comparison of lateral plate repairs of experimental oblique ilial fractures in cats

Paulick, Lutz; Knell, Sebastian Christoph; Smolders, Lucas A; Pozzi, Antonio; Schmierer, Philipp A (2022). Ex vivo comparison of lateral plate repairs of experimental oblique ilial fractures in cats. Veterinary Surgery, 51(1):191-201.

Abstract

Objective: To determine the biomechanical behavior of different plate systems used for oblique ilial fracture fixation in cats.
Study design: Ex vivo biomechanical study.
Sample population: Fifty fresh-frozen feline hemipelvises.
Methods: Standardized simple oblique ilial fractures were created and fixed via lateral plating, using different implant systems (10 fractures in each group) The systems were: (1) the Advanced Locking Plate System (ALPS-5); (2) the Advanced Locking Plate System (ALPS-6.5); (3) the Locking Compression Plate 2.0 (LCP); (4) the FIXIN 1.9-2.5 Series (FIXIN), and (5) the Dynamic Compression Plate 2.0 (DCP). Stepwise sinusoidal cyclic loading was applied until failure (10-mm displacement). The groups were compared with regard to construct stiffness and the number of cycles withstood before 1-, 2-, 5-, and 10-mm displacement.
Results: Bending stiffness was lower in ALPS-5 than in other specimens (P < .05). The ALPS-6.5 specimens withstood more cycles (P < .05) before 2-, 5-, and 10-mm displacement than the ALPS-5 and DCP specimens . The LCP and FIXIN specimens endured more cycles than DCP specimens before displaying 5- and 10-mm displacement (P < .05). The ALPS-6.5, FIXIN, and LCP specimens endured higher loads before failure than the DCP specimens (P < .05). Screw loosening occurred in all nonlocking specimens, and bone slicing occurred in all locking specimens.
Conclusion: The DCP and ALPS-5 constructs are less resistant to cyclic loading. Failure in nonlocking specimens involved screw loosening. It involved bone slicing in locking specimens.
Clinical significance: Both the plate size and the plate-screw interface are key to lateral plating success in cases of feline ilial fractures. The use of locking plates reduces the risk of the screw loosening in such cases.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:05 Vetsuisse Faculty > Veterinary Clinic > Department of Small Animals
Dewey Decimal Classification:570 Life sciences; biology
630 Agriculture
Scopus Subject Areas:Health Sciences > General Veterinary
Language:English
Date:January 2022
Deposited On:16 Feb 2023 17:30
Last Modified:23 Mar 2025 04:36
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:0161-3499
OA Status:Closed
Publisher DOI:https://doi.org/10.1111/vsu.13718
PubMed ID:34637153

Metadata Export

Statistics

Citations

Altmetrics

Downloads

0 downloads since deposited on 16 Feb 2023
0 downloads since 12 months

Authors, Affiliations, Collaborations

Similar Publications