Bilir, Halenur; Yuzbasioglu, Emir; Sayar, Gulsilay; Kilinc, Delal Dara; Bag, Harika Gozde Gozukara; Özcan, Mutlu (2022). CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed partial dentures bonded with two different resin cements: Up to 40 months clinical results of a randomized-controlled pilot study. Journal of Esthetic and Restorative Dentistry, 34(7):1122-1131.

Abstract

PURPOSE: This pilot study was part of a larger study planned for the future which aimed to compare the clinical success of two different resin cements used in the cementation of CAD/CAM single-retainer monolithic zirconia ceramic resin-bonded fixed dentures (RBFPDs).

METHODS: Twenty-four RBFPDs were fabricated with monolithic zirconia (Katana™ Zirconia HT, Kuraray Noritake Dental Inc, Tokyo, Japan). Panavia F2.0 (PF2.0; n = 12) and Panavia V5 (PV5; n = 12) were used for cementation. The survival period was defined as the time when the restoration was placed in the mouth and lasted until an irreparable damage occurred. The repairable failures were identified as relative and irreparable failures were identified as absolute failure. The survival rate of the RBFPDs was determined by the Kaplan-Meier estimator. Statistical significance was set at p < 0.05.

RESULTS: The mean observation times of the PF2.0 group and the PV5 group were 40.45 ± 6.15 months and 40.18 ± 6.41 months, respectively. Four failures occurred in the PF2.0 group. No failure was observed in the PV5 group. The curves of survival rate (PF2.0 = 80%, PV5 = 100%) showed no statistically significant difference (p = 0.031), although success rate (PF2.0 = 66.7%, PV5 = 100%) showed statistically significant difference (p = 0.317).

CONCLUSION: Up to 40 months mean follow-up period, performance of RBFPDs bonded with PV5 was better than with PF2.0.

CLINICAL SIGNIFICANCE: For clinicians, it is a matter of hesitation to apply single-retainer RBFPDs. This study contains results of 40 months (minimum 32, maximum 50.47 months) clinical follow-ups of single-retainer RBFPDs. These results will enlighten clinicians about the clinical success of the resin cement type for single-retainer monolithic zirconia ceramic RBFPDs.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Reconstructive Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > General Dentistry
Language:English
Date:October 2022
Deposited On:22 Feb 2023 16:26
Last Modified:29 Aug 2024 01:38
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:1496-4155
OA Status:Closed
Publisher DOI:https://doi.org/10.1111/jerd.12945
PubMed ID:35920051

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
5 citations in Web of Science®
7 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

0 downloads since deposited on 22 Feb 2023
0 downloads since 12 months

Authors, Affiliations, Collaborations

Similar Publications