Navigation auf zora.uzh.ch

Search ZORA

ZORA (Zurich Open Repository and Archive)

Associations between 3D surface scanner derived anthropometric measurements and body composition in a cross-sectional study

Guarnieri Lopez, Manuel; Matthes, Katarina L; Sob, Cynthia; Bender, Nicole; Staub, Kaspar (2023). Associations between 3D surface scanner derived anthropometric measurements and body composition in a cross-sectional study. European Journal of Clinical Nutrition, 77(10):972-981.

Abstract

Background
3D laser-based photonic scanners are increasingly used in health studies to estimate body composition. However, too little is known about whether various 3D body scan measures estimate body composition better than single standard anthropometric measures, and which body scans best estimate it. Furthermore, little is known about differences by sex and age.

Methods
105 men and 96 women aged between 18 and 90 years were analysed. Bioelectrical Impedance Analysis was used to estimate whole relative fat mass (RFM), visceral adipose tissue (VAT) and skeletal muscle mass index (SMI). An Anthroscan VITUSbodyscan was used to obtain 3D body scans (e.g. volumes, circumferences, lengths). To reduce the number of possible predictors that could predict RFM, VAT and SMI backward elimination was performed. With these selected predictors linear regression on the respective body compositions was performed and the explained variations were compared with models using standard anthropometric measurements (Body Mass Index (BMI), waist circumference (WC) and waist-to-height-ratio (WHtR)).

Results
Among the models based on standard anthropometric measures, WC performed better than BMI and WHtR in estimating body composition in men and women. The explained variations in models including body scan variables are consistently higher than those from standard anthropometrics models, with an increase in explained variations between 5% (RFM for men) and 10% (SMI for men). Furthermore, the explained variation of body composition was additionally increased when age and lifestyle variables were added. For each of the body composition variables, the number of predictors differed between men and women, but included mostly volumes and circumferences in the central waist/chest/hip area and the thighs.

Conclusions
3D scan models performed better than standard anthropometric measures models to predict body composition. Therefore, it is an advantage for larger health studies to look at body composition more holistically using 3D full body surface scans.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Evolutionary Medicine
Dewey Decimal Classification:610 Medicine & health
Uncontrolled Keywords:Nutrition and Dietetics, Medicine (miscellaneous)
Language:English
Date:1 October 2023
Deposited On:26 Jul 2023 09:07
Last Modified:28 Mar 2025 02:40
Publisher:Nature Publishing Group
ISSN:0954-3007
OA Status:Hybrid
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1038/s41430-023-01309-4
PubMed ID:37479806
Download PDF  'Associations between 3D surface scanner derived anthropometric measurements and body composition in a cross-sectional study'.
Preview
  • Content: Published Version
  • Language: English
  • Licence: Creative Commons: Attribution 4.0 International (CC BY 4.0)

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
4 citations in Web of Science®
4 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

13 downloads since deposited on 26 Jul 2023
13 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications