Navigation auf zora.uzh.ch

Search ZORA

ZORA (Zurich Open Repository and Archive)

Patient-specific quality assurance strategies for synthetic computed tomography in magnetic resonance-only radiotherapy of the abdomen

Dal Bello, Riccardo; Lapaeva, Mariia; La Greca Saint-Esteven, Agustina; Wallimann, Philipp; Günther, Manuel; Konukoglu, Ender; Andratschke, Nicolaus; Guckenberger, Matthias; Tanadini-Lang, Stephanie (2023). Patient-specific quality assurance strategies for synthetic computed tomography in magnetic resonance-only radiotherapy of the abdomen. Physics and Imaging in Radiation Oncology, 27:100464.

Abstract

BACKGROUND AND PURPOSE

The superior tissue contrast of magnetic resonance (MR) compared to computed tomography (CT) led to an increasing interest towards MR-only radiotherapy. For the latter, the dose calculation should be performed on a synthetic CT (sCT). Patient-specific quality assurance (PSQA) methods have not been established yet and this study aimed to assess several software-based solutions.

MATERIALS AND METHODS

A retrospective study was performed on 20 patients treated at an MR-Linac, which were selected to evenly cover four subcategories: (i) standard, (ii) air pockets, (iii) lung and (iv) implant cases. The neural network (NN) CycleGAN was adopted to generate a reference sCT, which was then compared to four PSQA methods: (A) water override of body, (B) five tissue classes with bulk densities, (C) sCT generated by a separate NN (pix2pix) and (D) deformed CT.

RESULTS

The evaluation of the dose endpoints demonstrated that while all methods A-D provided statistically equivalent results (p = 0.05) within the 2% level for the standard cases (i), only the methods C-D guaranteed the same result over the whole cohort. The bulk densities override was shown to be a valuable method in absence of lung tissue within the beam path.

CONCLUSION

The observations of this study suggested that the use of an additional sCT generated by a separate NN was an appropriate tool to perform PSQA of a sCT in an MR-only workflow at an MR-Linac. The time and dose endpoints requirements were respected, namely within 10 min and 2%.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Radiation Oncology
03 Faculty of Economics > Department of Informatics
08 Research Priority Programs > Digital Society Initiative
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Physical Sciences > Radiation
Health Sciences > Oncology
Health Sciences > Radiology, Nuclear Medicine and Imaging
Scope:Discipline-based scholarship (basic research)
Language:English
Date:26 June 2023
Deposited On:03 Aug 2023 08:43
Last Modified:29 Dec 2024 02:39
Publisher:Elsevier
ISSN:2405-6316
OA Status:Gold
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1016/j.phro.2023.100464
PubMed ID:37497188
Other Identification Number:PMCID: PMC10366576; merlin-id:24374
Download PDF  'Patient-specific quality assurance strategies for synthetic computed tomography in magnetic resonance-only radiotherapy of the abdomen'.
Preview
  • Content: Published Version
  • Language: English
  • Licence: Creative Commons: Attribution 4.0 International (CC BY 4.0)

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
7 citations in Web of Science®
7 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

35 downloads since deposited on 03 Aug 2023
28 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications