Navigation auf zora.uzh.ch

Search ZORA

ZORA (Zurich Open Repository and Archive)

Astigmatic neutrality in biaxial microincision cataract surgery

Kaufmann, C; Krishnan, A; Landers, J; Esterman, A; Thiel, M A; Goggin, M (2009). Astigmatic neutrality in biaxial microincision cataract surgery. Journal of Cataract and Refractive Surgery:1555-1562.

Abstract

PURPOSE: To assess the astigmatic effect of biaxial microincision cataract surgery (MICS) with insertion of an UltraChoice 1.0 Rollable Thinlens intraocular lens (IOL) in a sufficiently powered controlled study. SETTING: Queen Elizabeth Hospital, South Australian Institute of Ophthalmology, University of Adelaide, Adelaide, Australia. METHODS: Consecutive patients having biaxial MICS were evaluated prospectively. Keratometry was performed preoperatively and postoperatively. Vector analysis of the alteration in the keratometric cylinder was compared with that in control eyes not having surgery but having keratometry over a similar time frame. RESULTS: There were 76 eyes in the surgical group and 74 in the control group. The right-hand incision used for IOL insertion had a mean external opening width of 2.00 mm and a mean internal width of 1.89 mm. The left-hand incision measured a mean of 1.49 mm and 1.46 mm, respectively. There was no statistically significant difference between the surgical group and the routine variability in keratometry in the untreated control group in surgically induced astigmatism (surgical group, 0.57 diopter [D] +/- 0.05 [SEM]; control group, 0.54 +/- 0.06 D; P =.660) or the degree of mean calculated flattening effect at the right-hand incision (0.01 +/- 0.06 D and -0.05 +/- 0.05 D, respectively; P = .405) or at the left-hand incision (-0.06 +/- 0.05 D and 0.03 +/- 0.06 D, respectively; P = .283). CONCLUSION: Biaxial MICS with insertion of IOL through a temporal incision of 2.0 mm offers prospects of astigmatic neutrality in cataract surgery.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Ophthalmology Clinic
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Surgery
Health Sciences > Ophthalmology
Life Sciences > Sensory Systems
Language:English
Date:2009
Deposited On:14 Dec 2009 10:20
Last Modified:03 Mar 2025 02:41
Publisher:Elsevier
ISSN:0886-3350
OA Status:Closed
Publisher DOI:https://doi.org/10.1016/j.jcrs.2009.03.048
PubMed ID:19683152

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
23 citations in Web of Science®
31 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 14 Dec 2009
0 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications