Abstract

Steroid metabolites are increasingly in focus when searching for novel biomarkers in physiological mechanisms and their disorders. While major steroids such as progesterone and cortisol are well-researched and routinely determined to assess the health, particularly the reproductive status of mammals, the function of potentially biologically active progestogen and glucocorticoid metabolites is widely unexplored. One of the main reasons for this is the lack of comprehensive, sensitive, and specific analytical methods. This is particularly the case when analyzing matrices like milk or saliva obtained by non-invasive sampling with steroid concentrations often below those present in plasma. Therefore, a new UHPLC-HR-MS method based on an Ultimate UHPLC system equipped with an Acquity HSS T3 reversed-phase column and a Q Exactive™ mass spectrometer was developed, enabling the simultaneous chromatographic separation, detection and quantification of eleven isobaric glucocorticoids (11-dehydrocorticosterone (A), corticosterone (B), cortisol (F), cortisone (E), the tetrahydrocortisols (THF): 3α,5α-THF, 3α,5β-THF, 3β,5α-THF, 3β,5β-THF, and the tetrahydrocortisones (THE): 3α,5α-THE, 3α,5β-THE, 3β,5α-THE) and twelve progestogens (progesterone (P4), pregnenolone (P5), the dihydroprogesterones (DHP): 20α-DHP, 20β-DHP, 3α-DHP, 3β-DHP, 5α-DHP, 5β-DHP, and the tetrahydroprogesterones (THP): 3α,5α-THP, 3α,5β-THP, 3β,5α-THP, 3β,5β-THP) in bovine plasma, skimmed milk, and saliva. A simple liquid-liquid extraction (LLE) with MTBE (methyl tert-butyl ether) was used for sample preparation of 500 μL plasma, skimmed milk, and saliva. Heated electrospray ionization (HESI) with polarity switching was applied to analyze steroids in high-resolution full scan mode (HR-FS). The method validation covered the investigation of sensitivity, selectivity, curve fitting, carry-over, accuracy, precision, recovery, matrix effects and applicability. A high sensitivity in the range of pg mL−1 was achieved for all steroids suitable for the analysis of authentic samples.

Abstract

Steroid metabolites are increasingly in focus when searching for novel biomarkers in physiological mechanisms and their disorders. While major steroids such as progesterone and cortisol are well-researched and routinely determined to assess the health, particularly the reproductive status of mammals, the function of potentially biologically active progestogen and glucocorticoid metabolites is widely unexplored. One of the main reasons for this is the lack of comprehensive, sensitive, and specific analytical methods. This is particularly the case when analyzing matrices like milk or saliva obtained by non-invasive sampling with steroid concentrations often below those present in plasma. Therefore, a new UHPLC-HR-MS method based on an Ultimate UHPLC system equipped with an Acquity HSS T3 reversed-phase column and a Q Exactive™ mass spectrometer was developed, enabling the simultaneous chromatographic separation, detection and quantification of eleven isobaric glucocorticoids (11-dehydrocorticosterone (A), corticosterone (B), cortisol (F), cortisone (E), the tetrahydrocortisols (THF): 3α,5α-THF, 3α,5β-THF, 3β,5α-THF, 3β,5β-THF, and the tetrahydrocortisones (THE): 3α,5α-THE, 3α,5β-THE, 3β,5α-THE) and twelve progestogens (progesterone (P4), pregnenolone (P5), the dihydroprogesterones (DHP): 20α-DHP, 20β-DHP, 3α-DHP, 3β-DHP, 5α-DHP, 5β-DHP, and the tetrahydroprogesterones (THP): 3α,5α-THP, 3α,5β-THP, 3β,5α-THP, 3β,5β-THP) in bovine plasma, skimmed milk, and saliva. A simple liquid-liquid extraction (LLE) with MTBE (methyl tert-butyl ether) was used for sample preparation of 500 μL plasma, skimmed milk, and saliva. Heated electrospray ionization (HESI) with polarity switching was applied to analyze steroids in high-resolution full scan mode (HR-FS). The method validation covered the investigation of sensitivity, selectivity, curve fitting, carry-over, accuracy, precision, recovery, matrix effects and applicability. A high sensitivity in the range of pg mL−1 was achieved for all steroids suitable for the analysis of authentic samples.

Statistics

Citations

Dimensions.ai Metrics
1 citation in Web of Science®
1 citation in Scopus®
Google Scholar™

Altmetrics

Downloads

7 downloads since deposited on 18 Feb 2024
7 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:07 Faculty of Science > Department of Chemistry
Dewey Decimal Classification:540 Chemistry
Scopus Subject Areas:Physical Sciences > Analytical Chemistry
Physical Sciences > Environmental Chemistry
Life Sciences > Biochemistry
Physical Sciences > Spectroscopy
Uncontrolled Keywords:Spectroscopy, Environmental Chemistry, Biochemistry, Analytical Chemistry
Language:English
Date:1 January 2024
Deposited On:18 Feb 2024 10:45
Last Modified:30 Jun 2024 01:37
Publisher:Elsevier
ISSN:0003-2670
OA Status:Hybrid
Publisher DOI:https://doi.org/10.1016/j.aca.2023.342118
PubMed ID:38182350
  • Content: Published Version
  • Language: English
  • Licence: Creative Commons: Attribution 4.0 International (CC BY 4.0)