Efficient cleaning of a macro-structured micro-rough dental implant shoulder with a new coronal vertical groove design: A technical note


Brandenberger, Tim; Stübinger, Stefan; Gubler, Andrea; Schmidlin, Patrick R; Liu, Chun Ching (2023). Efficient cleaning of a macro-structured micro-rough dental implant shoulder with a new coronal vertical groove design: A technical note. Swiss Dental Journal, 133(11):730-734.

Abstract

This evaluation assessed the influence of a new implant shoulder design on cleanability using a now established in-vitro study model. Eight test (Botticelli, Di Meliora AG, Basel, Switzerland) and eight control implants (T3 Osseotite, ZimVie, Winterthur, Switzerland), were embedded in standardized defects in simulated bone. The implant surfaces were painted to be visually distinguishable and debrided with ultrasonic instruments (US) and an air powder waterjet device (AIR). Uncleaned implants served as positive controls. After the standardized cleaning, the implants were photographed and divided into three zones (upper marginal shoulder zone (A); lower marginal shoulder zone (B); fully threaded sub-shoulder zone (C)), and analyzed with an image processing software. On test implants, AIR was almost 100% efficacious compared to 80-90% with US, in both upper zones (A/B). In control implants, results of both AIR and US were almost 100% in zone A, but only 55-75% in zone B. In both implants, AIR showed statistically significant higher efficacy than US (P<0.05). Within the limitations of the present in-vitro model, a new macro-structured micro-rough dental implant shoulder with a new coronal vertical groove design shows similar cleanability in comparison to a smooth and machined surface.

Abstract

This evaluation assessed the influence of a new implant shoulder design on cleanability using a now established in-vitro study model. Eight test (Botticelli, Di Meliora AG, Basel, Switzerland) and eight control implants (T3 Osseotite, ZimVie, Winterthur, Switzerland), were embedded in standardized defects in simulated bone. The implant surfaces were painted to be visually distinguishable and debrided with ultrasonic instruments (US) and an air powder waterjet device (AIR). Uncleaned implants served as positive controls. After the standardized cleaning, the implants were photographed and divided into three zones (upper marginal shoulder zone (A); lower marginal shoulder zone (B); fully threaded sub-shoulder zone (C)), and analyzed with an image processing software. On test implants, AIR was almost 100% efficacious compared to 80-90% with US, in both upper zones (A/B). In control implants, results of both AIR and US were almost 100% in zone A, but only 55-75% in zone B. In both implants, AIR showed statistically significant higher efficacy than US (P<0.05). Within the limitations of the present in-vitro model, a new macro-structured micro-rough dental implant shoulder with a new coronal vertical groove design shows similar cleanability in comparison to a smooth and machined surface.

Statistics

Citations

Dimensions.ai Metrics

Altmetrics

Downloads

6 downloads since deposited on 31 Jan 2024
6 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Conservative and Preventive Dentistry
Dewey Decimal Classification:610 Medicine & health
Uncontrolled Keywords:debridement; dental implant; dental implant-abutment design; infection; peri-implantitis
Language:English
Date:9 June 2023
Deposited On:31 Jan 2024 08:40
Last Modified:07 Mar 2024 10:45
Publisher:Schweizerische Zahnärzte-Gesellschaft SSO
ISSN:2296-6498
OA Status:Gold
Free access at:Official URL. An embargo period may apply.
PubMed ID:37293828
  • Content: Published Version
  • Language: English