Abstract

Objective: To compare the stiffness and strength of three plate and rod fixation constructs applied to a feline tibial gap model.
Study design: Ex vivo study.
Sample population: Thirty-three unpaired tibiae obtained from skeletally mature cats.
Methods: The tibiae were randomly divided into three groups. The following implants were then applied to the feline tibiae prior to the creation of a 10 mm diaphyseal gap. Group 1: 2.4 mm locking compression plate (LCP) and 1.0 mm intramedullary pin (IMP). Group 2: 2.4 mm LCP and 1.6 mm IMP. Group 3: 2.7 mm LCP. Subsequently, each specimen was tested for torsion, axial compression, and axial load until construct failure. Student's t-tests were used to compare the torsional and axial stiffness, yield load, and maximum axial force.
Results: Group 2 had higher axial stiffness than group 3 (p = .013). Group 1 showed a lower maximum axial force and yield point than groups 2 and 3 (p < .01; p < .05, respectively). There were no among-group differences in torsional stiffness.
Conclusion: Constructs with a 2.4 mm LCP and 1.6 mm IMP provided the strongest and most rigid constructs in a feline tibia gap model.
Clinical significance: A plate-rod construct combining a 2.4 mm LCP and a 1.6 mm IMP is appropriate for achieving high implant stiffness and resisting maximum axial force in treatment of tibial fractures in cats.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:05 Vetsuisse Faculty > Veterinary Clinic > Department of Small Animals
Dewey Decimal Classification:630 Agriculture
570 Life sciences; biology
Scopus Subject Areas:Health Sciences > General Veterinary
Uncontrolled Keywords:General Veterinary
Language:English
Date:1 May 2024
Deposited On:01 Feb 2024 17:11
Last Modified:28 Apr 2025 01:39
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:0161-3499
OA Status:Hybrid
Publisher DOI:https://doi.org/10.1111/vsu.14038
PubMed ID:37818951
Download PDF  'Ex vivo biomechanical evaluation of 2.4 mm LCP plate rod constructs versus 2.7 mm LCP applied to the feline tibia'.
Preview
  • Content: Published Version
  • Language: English
  • Licence: Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)

Metadata Export

Statistics

Citations

Altmetrics

Downloads

4 downloads since deposited on 01 Feb 2024
3 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications