Wear at the implant–framework interface between titanium implant platform and the additively manufactured titanium and cobalt–chromium frameworks

Revilla‐León, Marta; Barmak, Abdul B; Rubenstein, Jeffrey; Özcan, Mutlu (2024). Wear at the implant–framework interface between titanium implant platform and the additively manufactured titanium and cobalt–chromium frameworks. Journal of Prosthodontics, 33(1):77-85.

Abstract

Purpose: To measure the wear at the implant interface between the Grade 4 titanium (Ti) of the implant and frameworks fabricated using two additively manufactured alloys (Ti alloy and cobalt–chromium [Co–Cr]) pre‐ and post‐artificial aging.
Material and methods: Three‐unit frameworks supported by two implants were additively manufactured (Atlantis; Dentsply Sirona) using Ti and Co–Cr dental alloys. Two implants (OsseoSpeed EV, Astra Tech; Dentsply Sirona) were torqued on each non‐engaging framework. The assembled implant–frameworks were secured into polyurethane foam blocks. Groups were created based on the material and surface assessed: framework (Ti‐framework and Co–Cr‐framework groups) and implant (Ti‐implant group). Two subgroups were created depending on the location: premolar (PM) and molar (M). Computed tomography images were obtained pre‐ (as manufactured) and post‐simulated mastication procedures. The pre‐ and post‐simulated mastication files of each specimen were aligned using the best‐fit algorithm using a metrology program. Wear was measured by calculating the volumetric discrepancies at the implant interface on 64 measurement points per area analyzed. Three‐way ANOVA and Tukey tests were used to analyze the data (α = 0.05).ResultsThe mean volumetric discrepancy values ranged from 0.8 to 3.1 µm among all the subgroups tested. The group (framework vs. implant) (p < 0.001) and tooth location (p < 0.001) were significant factors of the mean volumetric discrepancy values obtained. The framework group presented with significantly lower volumetric discrepancy mean values (1 µm) compared with the implant group (3 µm), whereas the premolar area obtained significantly lower mean volumetric discrepancy values (1.9 µm) compared with the molar location (2.3 µm).
Conclusions: Volumetric discrepancies were found at the implant–framework interface tested between the pre‐ and post‐artificial aging measurements ranging from 1 to 3 µm after 1,200,000 cyclic loading that simulated approximately 12 months of function.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Reconstructive Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > General Dentistry
Uncontrolled Keywords:General Dentistry
Language:English
Date:January 2024
Deposited On:16 Feb 2024 10:54
Last Modified:30 Dec 2024 02:56
Publisher:Wiley-Blackwell Publishing, Inc.
ISSN:1059-941X
OA Status:Closed
Publisher DOI:https://doi.org/10.1111/jopr.13652
Related URLs: (Publisher)
PubMed ID:36704924

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
1 citation in Web of Science®
3 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

2 downloads since deposited on 16 Feb 2024
2 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications