Accuracy and Reliability of Grip Strength Measurements: A Comparative Device Analysis

Gränicher, Pascale; Maurer, Yael; Spörri, Jörg; Haller, Bernhard; Swanenburg, Jaap; de Bie, Rob A; Lenssen, Ton A F; Scherr, Johannes (2024). Accuracy and Reliability of Grip Strength Measurements: A Comparative Device Analysis. Journal of Functional Morphology and Kinesiology, 9(4):274.

Abstract

Background: Grip strength is widely used as a surrogate parameter for functional status. The current gold standard, the JAMAR® Hydraulic Dynamometer (JAMAR® Hydraulic), presents challenges for individuals with painful finger joints or low grip strength. Therefore, the objective of this observational study was to assess comparability across the JAMAR® Smart, the Martin Vigorimeter and the gold standard. Additionally, the intrasubject and intersession reliability of all three devices were examined, which are essential for quality control before generating normative data. Methods: Forty healthy participants (aged 37.0 ± 11.3 years) were included, and a subset of 20 participants was randomly selected for retesting. Grip strength testing involved five attempts per measurement device. Results: Intrasubject reliability was excellent (ICC3,1: 0.91–0.97), and a strong correlation (ICC3,1: 0.90–0.98) was found between the first attempt and the best of five as well as between the best of two or three attempts and the best of five, demonstrating robust reliability across multiple measures. Intersession reliability was good to excellent (ICC3,1: 0.85–0.97) across all three devices, which was confirmed by Bland–Altman analysis. The PCC (r) revealed moderate to very strong agreement with the current gold standard JAMAR® Hydraulic (r = 0.68–0.98), with increased differences between the Martin Vigorimeter and the JAMAR® Hydraulic measurements, particularly at low and high values. Conclusions: The proposed devices are suitable for test-retest analysis with 2–3 attempts. Despite high correlations between all three devices, the diverging levels of agreement between the Martin Vigorimeter and the established gold standard warrant caution against using these devices interchangeably.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Anatomy
04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Language:English
Date:16 December 2024
Deposited On:24 Dec 2024 07:31
Last Modified:30 Jun 2025 02:06
Publisher:MDPI Publishing
ISSN:2411-5142
OA Status:Gold
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.3390/jfmk9040274
PubMed ID:39728258
Project Information:
  • Funder: Deutsche Gesellschaft für Physiotherapie Wissenschaften
  • Grant ID:
  • Project Title:
Download PDF  'Accuracy and Reliability of Grip Strength Measurements: A Comparative Device Analysis'.
Preview
  • Content: Published Version
  • Language: English
  • Licence: Creative Commons: Attribution 4.0 International (CC BY 4.0)

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
1 citation in Web of Science®
1 citation in Scopus®
Google Scholar™

Altmetrics

Downloads

14 downloads since deposited on 24 Dec 2024
14 downloads since 12 months
Detailed statistics