Navigation auf zora.uzh.ch

Search ZORA

ZORA (Zurich Open Repository and Archive)

Migration von ZORA auf die Software DSpace

ZORA will change to a new software on 8th September 2025. Please note: deadline for new submissions is 21th July 2025!

Information & dates for training courses can be found here: Information on Software Migration.

Quantifying Tendon Degeneration Using Magic Angle Insensitive Ultra-Short Echo Time Magnetization Transfer: A Phantom Study in Bovine Tendons

Feuerriegel, Georg C; Marth, Adrian A; Goller, Sophia S; Hilbe, Monika; Sommer, Stefan; Sutter, Reto (2024). Quantifying Tendon Degeneration Using Magic Angle Insensitive Ultra-Short Echo Time Magnetization Transfer: A Phantom Study in Bovine Tendons (2024/04/10). Investigative Radiology, 59(10):691-698.

Abstract

OBJECTIVES
The aim of this study was to qualitatively and quantitatively assess changes in bovine flexor tendons before and after collagen degradation and at different angles in relation to the static B 0 field using 3-dimensional ultra-short echo time (UTE) magnetization transfer (MT) imaging within a clinically feasible acquisition time.

MATERIALS AND METHODS
Eight bovine flexor tendons were examined at 3 T magnetic resonance imaging including 3-dimensional UTE MT and UTE T2* research application sequences (acquired within 4:04 and 6:38 minutes, respectively) before and after enzyme-induced degradation. The tendons were divided into 2 groups: group 1 (controls) treated with phosphate-buffered saline and group 2 treated with collagenase I to induce collagen degeneration. Magnetic resonance imaging was repeated at 0, 27, 55, and 90 degrees to the B 0 field. To calculate quantitative tissue properties, all tendons were semiautomatically segmented, and changes in quantitative UTE T2* and UTE MT ratios (MTRs) were compared at different angles and between groups. In addition to descriptive statistics, the coefficient of variation was calculated to compare UTE MT and UTE T2* imaging.

RESULTS
Ultra-short echo time MTR showed a significantly lower coefficient of variation compared with UTE T2* values, indicating a more robust imaging method (UTE MTR 9.64%-11.25%, UTE T2* 18.81%-24.06%, P < 0.001). Both methods showed good performance in detecting degenerated tendons using histopathology as reference standard, with UTE MT imaging having a better area under the curve than UTE T2* mapping (0.918 vs 0.865). Falsely high UTE T2* values were detected at the 55 degrees acquisition angle, whereas UTE MTR values were robust, that is, insensitive to the MAE.

CONCLUSIONS
Ultra-short echo time MT imaging is a reliable method for quantifying tendon degeneration that is robust to the MAE and can be acquired in a clinically reasonable time.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
05 Vetsuisse Faculty > Veterinärwissenschaftliches Institut > Institute of Veterinary Pathology
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Radiology, Nuclear Medicine and Imaging
Uncontrolled Keywords:Animals Cattle *Phantoms, Imaging *Magnetic Resonance Imaging/methods *Tendons/diagnostic imaging/pathology Imaging, Three-Dimensional/methods Sensitivity and Specificity Reproducibility of Results Image Interpretation, Computer-Assisted/methods
Language:English
Date:1 October 2024
Deposited On:29 Jan 2025 07:33
Last Modified:30 Jun 2025 02:08
Publisher:Lippincott Williams & Wilkins
Edition:2024/04/10
ISSN:0020-9996
OA Status:Hybrid
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1097/RLI.0000000000001074
PubMed ID:38598670
Download PDF  'Quantifying Tendon Degeneration Using Magic Angle Insensitive Ultra-Short Echo Time Magnetization Transfer: A Phantom Study in Bovine Tendons'.
Preview
  • Content: Published Version
  • Language: English
  • Licence: Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
2 citations in Web of Science®
2 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

9 downloads since deposited on 29 Jan 2025
9 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications