Header

UZH-Logo

Maintenance Infos

Alignment of the CMS silicon strip tracker during stand-alone commissioning


Adam, W; et al (2009). Alignment of the CMS silicon strip tracker during stand-alone commissioning. Journal of Instrumentation, 4(7):T07001.

Abstract

The results of the CMS tracker alignment analysis are presented using the data from cosmic tracks, optical survey information, and the laser alignment system at the Tracker Integration Facility at CERN. During several months of operation in the spring and summer of 2007, about five million cosmic track events were collected with a partially active CMS Tracker. This allowed us to perform first alignment of the active silicon modules with the cosmic tracks using three different statistical approaches; validate the survey and laser alignment system performance; and test the stability of Tracker structures under various stresses and temperatures ranging from +15 °C to −15 °C. Comparison with simulation shows that the achieved alignment precision in the barrel part of the tracker leads to residual distributions similar to those obtained with a random misalignment of 50 (80) μm RMS in the outer (inner) part of the barrel.

Abstract

The results of the CMS tracker alignment analysis are presented using the data from cosmic tracks, optical survey information, and the laser alignment system at the Tracker Integration Facility at CERN. During several months of operation in the spring and summer of 2007, about five million cosmic track events were collected with a partially active CMS Tracker. This allowed us to perform first alignment of the active silicon modules with the cosmic tracks using three different statistical approaches; validate the survey and laser alignment system performance; and test the stability of Tracker structures under various stresses and temperatures ranging from +15 °C to −15 °C. Comparison with simulation shows that the achieved alignment precision in the barrel part of the tracker leads to residual distributions similar to those obtained with a random misalignment of 50 (80) μm RMS in the outer (inner) part of the barrel.

Statistics

Citations

Dimensions.ai Metrics
8 citations in Web of Science®
15 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

148 downloads since deposited on 21 Jan 2010
9 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:07 Faculty of Science > Physics Institute
Dewey Decimal Classification:530 Physics
Scopus Subject Areas:Physical Sciences > Mathematical Physics
Physical Sciences > Instrumentation
Language:English
Date:2009
Deposited On:21 Jan 2010 18:04
Last Modified:27 Jun 2022 13:40
Publisher:Institute of Physics Publishing
ISSN:1748-0221
OA Status:Hybrid
Publisher DOI:https://doi.org/10.1088/1748-0221/4/07/T07001