Header

UZH-Logo

Maintenance Infos

Quantitative analysis of stress echocardiograms in healthy horses with 2-dimensional (2D) echocardiography, anatomical M-mode, tissue Doppler imaging, and 2D speckle tracking


Schefer, Kathrin Daniela. Quantitative analysis of stress echocardiograms in healthy horses with 2-dimensional (2D) echocardiography, anatomical M-mode, tissue Doppler imaging, and 2D speckle tracking. 2010, University of Zurich, Vetsuisse Faculty.

Abstract

Kathrin Daniela Schefer, 2010 Vetsuisse-Fakultät Zürich Departement für Pferde, Sekretariat: Frau G. Schmid, gschmid@vetclinics.uzh.ch

Background: Stress echocardiography is used to diagnose myocardial dysfunction in horses, but current methods are not well standardized. The influence of heart rate (HR) on measurements is largely unknown. Objectives: To investigate the use of two-dimensional echocardiography (2DE), anatomical M-mode (AMM), tissue Doppler imaging (TDI), and 2D speckle tracking (2DST) at rest and after exercise for quantification of regional and global left- ventricular (LV) function. Animals: Five athletic Warmblood horses; 11.6±3.6 years; 529±48 kg. Methods: Prospective study. Three separate echocardiographic examinations were performed before and over 5 min after treadmill exercise using 2DE and pulsed-wave TDI. Offline analyses were performed at baseline and after exercise at HR 120, 110, 100, 90, 80 min-1. Results: Quantitative analyses of stress echocardiograms were feasible in all horses. None of the AMM indices changed significantly after exercise. Stroke volume and ejection fraction by 2DE and strain by 2DST decreased, whereas strain rate by 2DST increased significantly at HR >100min-1. TDI analyses were technically difficult and provided little information. Conclusions: Volumetric indices by 2DE and strain and strain rate by 2DST are applicable for quantitative assessment of stress echocardiograms. In healthy horses, they are significantly altered at a HR >100 min-1 and need to be evaluated in view of the instantaneous HR. Further investigations are needed to define the clinical value of stress echocardiography in horses with cardiac disease. Quantitative Analyse von Stressechokardiogrammen bei gesunden Pferden mittels zweidimensionaler (2D) Echokardiographie, Anatomical M-Mode, Tissue Doppler Imaging und 2D Speckle Tracking

Hintergrund: Stressechokardiographie wird beim Pferd zur Diagnose belastungsinduzierter Myokarddysfunktionen verwendet. Die klinische Relevanz, die Zuverlässigkeit und der Einfluss der Herzfrequenz (HF) sind aber weitgehend unbekannt. Ziel: Die Anwendung von zwei-dimensionaler Echokardiographie (2DE), anatomical M-Mode (AMM), Tissue Doppler Imaging (TDI) und 2D Speckle Tracking (2DST) in Ruhe und nach Belastung, um die regionale und globale linksventrikuläre (LV) Funktion quantitativ zu beurteilen. Tiere: Fünf trainierte Warmblutpferde; 11.6±3.6 Jahre alt; 529±48 kg. Methoden: Prospektive Studie. Die Pferde wurden 3 Untersuchungen mittels 2DE und TDI vor und während 5 min nach Laufbandbelastung unterzogen. Die Messungen erfolgten offline und wurden in Ruhe und nach Belastung bei HF 120, 110, 100, 90, 80 min-1 erhoben. Resultate: Quantitative Analysen waren bei allen Pferden durchführbar. Schlagvolumen und Ejection Fraction mittels 2DE und Strain mittels 2DST waren signifikant reduziert, während Strain Rate mittels 2DST signifikant erhöht war bei HF >100 min-1. TDI-Analysen waren unzuverlässig. Schlussfolgerungen: 2DE-basierte volumetrische Indizes und 2DST-basierter Strain und Strain Rate sind für eine quantitative Analyse von Stressechokardiogrammen beim Pferd anwendbar. Beim gesunden Pferd sind diese Indizes bei einer HF >100min-1 signifikant verändert. Weitere Untersuchungen sind nötig, um die klinische Relevanz der Stressechokardiographie beim herzkranken Pferd abzuschätzen.

Abstract

Kathrin Daniela Schefer, 2010 Vetsuisse-Fakultät Zürich Departement für Pferde, Sekretariat: Frau G. Schmid, gschmid@vetclinics.uzh.ch

Background: Stress echocardiography is used to diagnose myocardial dysfunction in horses, but current methods are not well standardized. The influence of heart rate (HR) on measurements is largely unknown. Objectives: To investigate the use of two-dimensional echocardiography (2DE), anatomical M-mode (AMM), tissue Doppler imaging (TDI), and 2D speckle tracking (2DST) at rest and after exercise for quantification of regional and global left- ventricular (LV) function. Animals: Five athletic Warmblood horses; 11.6±3.6 years; 529±48 kg. Methods: Prospective study. Three separate echocardiographic examinations were performed before and over 5 min after treadmill exercise using 2DE and pulsed-wave TDI. Offline analyses were performed at baseline and after exercise at HR 120, 110, 100, 90, 80 min-1. Results: Quantitative analyses of stress echocardiograms were feasible in all horses. None of the AMM indices changed significantly after exercise. Stroke volume and ejection fraction by 2DE and strain by 2DST decreased, whereas strain rate by 2DST increased significantly at HR >100min-1. TDI analyses were technically difficult and provided little information. Conclusions: Volumetric indices by 2DE and strain and strain rate by 2DST are applicable for quantitative assessment of stress echocardiograms. In healthy horses, they are significantly altered at a HR >100 min-1 and need to be evaluated in view of the instantaneous HR. Further investigations are needed to define the clinical value of stress echocardiography in horses with cardiac disease. Quantitative Analyse von Stressechokardiogrammen bei gesunden Pferden mittels zweidimensionaler (2D) Echokardiographie, Anatomical M-Mode, Tissue Doppler Imaging und 2D Speckle Tracking

Hintergrund: Stressechokardiographie wird beim Pferd zur Diagnose belastungsinduzierter Myokarddysfunktionen verwendet. Die klinische Relevanz, die Zuverlässigkeit und der Einfluss der Herzfrequenz (HF) sind aber weitgehend unbekannt. Ziel: Die Anwendung von zwei-dimensionaler Echokardiographie (2DE), anatomical M-Mode (AMM), Tissue Doppler Imaging (TDI) und 2D Speckle Tracking (2DST) in Ruhe und nach Belastung, um die regionale und globale linksventrikuläre (LV) Funktion quantitativ zu beurteilen. Tiere: Fünf trainierte Warmblutpferde; 11.6±3.6 Jahre alt; 529±48 kg. Methoden: Prospektive Studie. Die Pferde wurden 3 Untersuchungen mittels 2DE und TDI vor und während 5 min nach Laufbandbelastung unterzogen. Die Messungen erfolgten offline und wurden in Ruhe und nach Belastung bei HF 120, 110, 100, 90, 80 min-1 erhoben. Resultate: Quantitative Analysen waren bei allen Pferden durchführbar. Schlagvolumen und Ejection Fraction mittels 2DE und Strain mittels 2DST waren signifikant reduziert, während Strain Rate mittels 2DST signifikant erhöht war bei HF >100 min-1. TDI-Analysen waren unzuverlässig. Schlussfolgerungen: 2DE-basierte volumetrische Indizes und 2DST-basierter Strain und Strain Rate sind für eine quantitative Analyse von Stressechokardiogrammen beim Pferd anwendbar. Beim gesunden Pferd sind diese Indizes bei einer HF >100min-1 signifikant verändert. Weitere Untersuchungen sind nötig, um die klinische Relevanz der Stressechokardiographie beim herzkranken Pferd abzuschätzen.

Statistics

Downloads

0 downloads since deposited on 25 Jan 2011
0 downloads since 12 months

Additional indexing

Other titles:Quantitative analysis of stress echocardiograms in horses using two-dimensional echocardiography, anatomical M-mode, tissue Doppler imaging, and two-dimensional speckle tracking
Item Type:Dissertation (monographical)
Referees:Schwarzwald Colin C, Glaus Tony
Communities & Collections:05 Vetsuisse Faculty > Veterinary Clinic > Equine Department
UZH Dissertations
Dewey Decimal Classification:570 Life sciences; biology
630 Agriculture
Language:English
Place of Publication:Zürich
Date:2010
Deposited On:25 Jan 2011 07:41
Last Modified:10 Feb 2019 04:10
Number of Pages:0
Additional Information:Vorzeitig publiziert in und Sonderdruck aus: J Vet Intern Med 2010;24:918-931 Artikel mit 3 Co-Autoren verfasst
OA Status:Green
Related URLs:https://www.recherche-portal.ch/primo-explore/fulldisplay?docid=ebi01_prod006170163&context=L&vid=ZAD&search_scope=default_scope&tab=default_tab&lang=de_DE (Library Catalogue)