Dörig, P; Stiefel, P; Behr, P; Sarajlic, E; Bijl, D; Gabi, M; Vörös, J; Vorholt, J A; Zambelli, T (2010). Force-controlled spatial manipulation of viable mammalian cells and micro-organisms by means of FluidFM technology. Applied Physics Letters, 97:023701.

Abstract

The FluidFM technology uses microchanneled atomic force microscope cantilevers that are fixed to a drilled atomic force microscope cantilevers probeholder. A continuous fluidic circuit is thereby achieved extending from an external liquid reservoir, through the probeholder and the hollow cantilever to the tip aperture. In this way, both overpressure and an underpressure can be applied to the liquid reservoir and hence to the built-in fluidic circuit. We describe in this letter how standard atomic force microscopy in combination with regulated pressure differences inside the microchanneled cantilevers can be used to displace living organisms with micrometric precision in a nondestructive way. The protocol is applicable to both eukaryotic and prokaryotic cells (e.g., mammalian cells, yeasts, and bacteria) in physiological buffer. By means of this procedure, cells can also be transferred from one glass slide to another one or onto an agar medium.

Abstract

The FluidFM technology uses microchanneled atomic force microscope cantilevers that are fixed to a drilled atomic force microscope cantilevers probeholder. A continuous fluidic circuit is thereby achieved extending from an external liquid reservoir, through the probeholder and the hollow cantilever to the tip aperture. In this way, both overpressure and an underpressure can be applied to the liquid reservoir and hence to the built-in fluidic circuit. We describe in this letter how standard atomic force microscopy in combination with regulated pressure differences inside the microchanneled cantilevers can be used to displace living organisms with micrometric precision in a nondestructive way. The protocol is applicable to both eukaryotic and prokaryotic cells (e.g., mammalian cells, yeasts, and bacteria) in physiological buffer. By means of this procedure, cells can also be transferred from one glass slide to another one or onto an agar medium.

Statistics

Citations

Dimensions.ai Metrics
5 citations in Web of Science®
6 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

169 downloads since deposited on 30 Jan 2011
36 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Scopus Subject Areas:Physical Sciences > General Physics and Astronomy
Language:English
Date:2010
Deposited On:30 Jan 2011 19:38
Last Modified:23 Jan 2022 18:08
Publisher:American Institute of Physics
ISSN:0003-6951
OA Status:Green
Free access at:Publisher DOI. An embargo period may apply.
Publisher DOI:https://doi.org/10.1063/1.3462979
  • Content: Published Version