Header

UZH-Logo

Maintenance Infos

Noncontrast SSFP pulmonary vein magnetic resonance angiography: impact of off-resonance and flow


Hu, P; Stoeck, C T; Smink, J; Peters, D C; Ngo, L; Goddu, B; Kissinger, K V; Goepfert, L A; Chan, J; Hauser, T H; Rofsky, N M; Manning, W J; Nezafat, R (2010). Noncontrast SSFP pulmonary vein magnetic resonance angiography: impact of off-resonance and flow. Journal of Magnetic Resonance Imaging, 32(5):1255-1261.

Abstract

PURPOSE: To investigate pulmonary vein (PV) off-resonance and blood flow as causes of signal void artifacts in noncontrast steady-state-free-precession (SSFP) PV magnetic resonance angiography (MRA).

MATERIALS AND METHODS: PV blood off-resonance was measured on 11 healthy adult subjects and 10 atrial fibrillation (AF) patients. Noncontrast PV MRA was performed using a 3D slab-selective SSFP sequence at 1.5T on seven healthy subjects with signal profile shifts of 0-125 Hz. The time-resolved blood flow velocity of the PVs was measured on five healthy subjects. The impact of flow was studied on six healthy subjects, on whom SSFP PV MRA was acquired twice with the electrocardiogram (ECG) trigger delay corresponding to low and high flow, respectively.

RESULTS: The PV off-resonances were 97 ± 27 Hz, 65 ± 20 Hz, 74 ± 25 Hz, and 52 ± 17 Hz for right inferior, left inferior, right superior, and left superior PVs, respectively, on healthy subjects, and 74 ± 20 Hz, 38 ± 9 Hz, 51 ± 20 Hz, and 28 ± 11 Hz on AF patients (P<0.01 for all). The off-resonance caused severe signal voids in the PVs. Signal acquired during mid-diastole with high PV flow caused additional signal voids in the left atrium, which was reduced by setting the ECG trigger delay to late-diastole.

CONCLUSION: PV off-resonance and flow causes signal void artifacts in noncontrast 3D slab-selective SSFP PV MRA.

Abstract

PURPOSE: To investigate pulmonary vein (PV) off-resonance and blood flow as causes of signal void artifacts in noncontrast steady-state-free-precession (SSFP) PV magnetic resonance angiography (MRA).

MATERIALS AND METHODS: PV blood off-resonance was measured on 11 healthy adult subjects and 10 atrial fibrillation (AF) patients. Noncontrast PV MRA was performed using a 3D slab-selective SSFP sequence at 1.5T on seven healthy subjects with signal profile shifts of 0-125 Hz. The time-resolved blood flow velocity of the PVs was measured on five healthy subjects. The impact of flow was studied on six healthy subjects, on whom SSFP PV MRA was acquired twice with the electrocardiogram (ECG) trigger delay corresponding to low and high flow, respectively.

RESULTS: The PV off-resonances were 97 ± 27 Hz, 65 ± 20 Hz, 74 ± 25 Hz, and 52 ± 17 Hz for right inferior, left inferior, right superior, and left superior PVs, respectively, on healthy subjects, and 74 ± 20 Hz, 38 ± 9 Hz, 51 ± 20 Hz, and 28 ± 11 Hz on AF patients (P<0.01 for all). The off-resonance caused severe signal voids in the PVs. Signal acquired during mid-diastole with high PV flow caused additional signal voids in the left atrium, which was reduced by setting the ECG trigger delay to late-diastole.

CONCLUSION: PV off-resonance and flow causes signal void artifacts in noncontrast 3D slab-selective SSFP PV MRA.

Statistics

Citations

Dimensions.ai Metrics
19 citations in Web of Science®
19 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 17 Feb 2011
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Scopus Subject Areas:Health Sciences > Radiology, Nuclear Medicine and Imaging
Uncontrolled Keywords:Radiology Nuclear Medicine and imaging
Language:English
Date:2010
Deposited On:17 Feb 2011 08:20
Last Modified:23 Jan 2022 18:27
Publisher:Wiley-Blackwell
ISSN:1053-1807
OA Status:Closed
Publisher DOI:https://doi.org/10.1002/jmri.22356
PubMed ID:21031533