Navigation auf zora.uzh.ch

Search ZORA

ZORA (Zurich Open Repository and Archive)

Effect of changing pulse rate on profile parameters of perceptual thresholds and loudness comfort levels and relation to ECAP thresholds in recipients of the Nucleus CI24RE device.

Wesarg, T; Battmer, R-D; Garrido, L C; Dillier, N; Garcia-Ibáñez, L; Hey, M; Macias, A R; Irujo, A H; Morsnowski, A; Offeciers, E F; Zarowski, A; Pesch, J; Rypkema, G; Smoorenburg, G F (2010). Effect of changing pulse rate on profile parameters of perceptual thresholds and loudness comfort levels and relation to ECAP thresholds in recipients of the Nucleus CI24RE device. International journal of audiology, 49(10):775-87.

Abstract

The Nucleus CI24RE ‘Freedom' device offers higher stimulation rates and lower noise levels in action potential measurements (ECAPs) than previous devices. A study including ten European implant teams showed that the effect of changes in rate from 250 to 3500 pulses per second on tilt and curvature of the T and C profiles is insignificant. When changing rate one may change the levels at all electrodes by the same amount. Using an automated procedure ECAPs could be measured quickly and reliably at a noise level of only 1 microV, this did not result in improved correlations between the tilt and curvature parameters of the ECAP profiles and those of the T and C profiles. Average C levels appear to differ markedly among implant centers; a better assessment protocol is required. When increasing stimulus rate one should take into account that this requires higher pulse charges per second and more power consumption.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Otorhinolaryngology
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Social Sciences & Humanities > Language and Linguistics
Social Sciences & Humanities > Linguistics and Language
Health Sciences > Speech and Hearing
Language:English
Date:2010
Deposited On:18 Feb 2011 11:37
Last Modified:14 Jan 2025 04:42
Publisher:Informa-Healthcare
ISSN:1499-2027
OA Status:Closed
Publisher DOI:https://doi.org/10.3109/14992027.2010.492401
PubMed ID:20666693
Full text not available from this repository.

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
12 citations in Web of Science®
16 citations in Scopus®
Google Scholar™

Altmetrics

Authors, Affiliations, Collaborations

Similar Publications