Abstract

PURPOSE: Conventional time-domain optical coherence tomography (OCT) has been shown to provide reproducible retinal nerve fiber layer (RNFL) measurements. Recently, high-speed, high-resolution Fourier-domain 3D-OCT has been introduced to improve OCT quality. It can provide 6-mm(2) high-density scans to provide RNFL thickness measurements. The purpose of this study was to test the reproducibility of 3D-OCT RNFL thickness measurements in healthy volunteers. METHODS: Thirty-eight eyes were included in the study. High-density 6-mm(2) 3D scans were registered by two independent operators. RNFL thickness was calculated for eight areas corresponding to the ETDRS areas and for two ring areas. The ETDRS grid was centered on the optic disc. Intraclass correlation coefficients (ICC) and coefficients of variation (COV) were calculated. Interobserver reproducibility was visualized by using Bland-Altman analysis. RESULTS: Intrasession reproducibility was good with a mean ICC of 0.90. The mean COV for operator 1 and 2 was 4.2% and 4%, respectively (range, 1.9%-6.7%). Highest reproducibility was found for the two ring areas and the superior and inferior quadrants. Mean differences in RNFL thickness measurements for ring 1 and 2 between operator 1 and 2 were 0.9 microm (limits of agreement, -11.4 to +9.6 microm) and 0.1 microm (limits of agreement -4.1 to +3.9 microm), respectively. CONCLUSIONS: 3D-OCT RNFL thickness measurements in healthy volunteers showed good intra- and interobserver reproducibility. 3D-OCT provides more RNFL thickness information compared to conventional time-domain OCT measurements and may be useful for the management of glaucoma and other optic neuropathies.

Abstract

PURPOSE: Conventional time-domain optical coherence tomography (OCT) has been shown to provide reproducible retinal nerve fiber layer (RNFL) measurements. Recently, high-speed, high-resolution Fourier-domain 3D-OCT has been introduced to improve OCT quality. It can provide 6-mm(2) high-density scans to provide RNFL thickness measurements. The purpose of this study was to test the reproducibility of 3D-OCT RNFL thickness measurements in healthy volunteers. METHODS: Thirty-eight eyes were included in the study. High-density 6-mm(2) 3D scans were registered by two independent operators. RNFL thickness was calculated for eight areas corresponding to the ETDRS areas and for two ring areas. The ETDRS grid was centered on the optic disc. Intraclass correlation coefficients (ICC) and coefficients of variation (COV) were calculated. Interobserver reproducibility was visualized by using Bland-Altman analysis. RESULTS: Intrasession reproducibility was good with a mean ICC of 0.90. The mean COV for operator 1 and 2 was 4.2% and 4%, respectively (range, 1.9%-6.7%). Highest reproducibility was found for the two ring areas and the superior and inferior quadrants. Mean differences in RNFL thickness measurements for ring 1 and 2 between operator 1 and 2 were 0.9 microm (limits of agreement, -11.4 to +9.6 microm) and 0.1 microm (limits of agreement -4.1 to +3.9 microm), respectively. CONCLUSIONS: 3D-OCT RNFL thickness measurements in healthy volunteers showed good intra- and interobserver reproducibility. 3D-OCT provides more RNFL thickness information compared to conventional time-domain OCT measurements and may be useful for the management of glaucoma and other optic neuropathies.

Statistics

Citations

Dimensions.ai Metrics
85 citations in Web of Science®
89 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

198 downloads since deposited on 04 Dec 2008
18 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Ophthalmology Clinic
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Ophthalmology
Life Sciences > Sensory Systems
Life Sciences > Cellular and Molecular Neuroscience
Language:English
Date:1 August 2008
Deposited On:04 Dec 2008 15:13
Last Modified:26 Jun 2022 07:30
Publisher:Association for Research in Vision and Ophthalmology
ISSN:0146-0404
OA Status:Hybrid
Publisher DOI:https://doi.org/10.1167/iovs.07-1435
PubMed ID:18676630
  • Content: Accepted Version