Quantitative perfusion analysis of malignant liver tumors: Dynamic computed tomography and contrast-enhanced ultrasound


Goetti, R; Reiner, Caecilia S; Knuth, A; Klotz, E; Stenner, F; Samaras, P; Alkadhi, Hatem (2012). Quantitative perfusion analysis of malignant liver tumors: Dynamic computed tomography and contrast-enhanced ultrasound. Investigative Radiology, 47(1):18-24.

Abstract

OBJECTIVE:: To prospectively analyze the correlation between quantitative parameters of perfusion derived from dynamic contrast-enhanced CT (DCE-CT) and contrast-enhanced ultrasound (DCE-US) in patients with malignant liver tumors. MATERIALS AND METHODS:: Thirty patients (mean age: 59.4 ± 12.3 years) with primary malignant liver tumors or hepatic metastases of various origin underwent DCE-CT (4D spiral mode, scan range, 14.8 cm; 15 scans; cycle time, 3 seconds) and DCE-US (low mechanical index, <0.1, 2.4 mL microbubbles). DCE-CT and DCE-US images were evaluated by 2 radiologists regarding quantitative perfusion parameters including arterial liver perfusion (ALP), portal-venous perfusion (PVP), and total perfusion (P = ALP + PVP) from DCE-CT, as well as blood inflow velocity (B) and the normalized slope within the calculation range (CVan) from DCE-US. RESULTS:: Quantitative assessment was possible with DCE-CT in 12/30 (40%) patients before and in all patients after automated motion correction. With DCE-US, quantitative assessment could not be performed in 9/30 (30.0%) patients due to respiratory motion. Interreader agreements for quantitative perfusion analysis were good with DCE-CT (r = 0.640-0.892, each P < 0.001) and DCE-US (r = 0.761-0.909, each P < 0.001). Moderate significant correlations were found between the perfusion parameters from DCE-CT (P, ALP) and DCE-US (B, CVan) (r = 0.446-0.621, each P < 0.05). No significant correlations were found between PVP from CT and perfusion parameters from DCE-US (B, CVan; each P = nonsignificant). CONCLUSIONS:: Quantitative evaluation of DCE-CT data was feasible in all patients after automated motion correction, whereas DCE-US data could not be quantitatively evaluated in 30% of patients due to respiratory motion and lack of motion correction software. Quantitative arterial perfusion analysis showed moderate significant correlations for blood flow parameters among modalities.

Abstract

OBJECTIVE:: To prospectively analyze the correlation between quantitative parameters of perfusion derived from dynamic contrast-enhanced CT (DCE-CT) and contrast-enhanced ultrasound (DCE-US) in patients with malignant liver tumors. MATERIALS AND METHODS:: Thirty patients (mean age: 59.4 ± 12.3 years) with primary malignant liver tumors or hepatic metastases of various origin underwent DCE-CT (4D spiral mode, scan range, 14.8 cm; 15 scans; cycle time, 3 seconds) and DCE-US (low mechanical index, <0.1, 2.4 mL microbubbles). DCE-CT and DCE-US images were evaluated by 2 radiologists regarding quantitative perfusion parameters including arterial liver perfusion (ALP), portal-venous perfusion (PVP), and total perfusion (P = ALP + PVP) from DCE-CT, as well as blood inflow velocity (B) and the normalized slope within the calculation range (CVan) from DCE-US. RESULTS:: Quantitative assessment was possible with DCE-CT in 12/30 (40%) patients before and in all patients after automated motion correction. With DCE-US, quantitative assessment could not be performed in 9/30 (30.0%) patients due to respiratory motion. Interreader agreements for quantitative perfusion analysis were good with DCE-CT (r = 0.640-0.892, each P < 0.001) and DCE-US (r = 0.761-0.909, each P < 0.001). Moderate significant correlations were found between the perfusion parameters from DCE-CT (P, ALP) and DCE-US (B, CVan) (r = 0.446-0.621, each P < 0.05). No significant correlations were found between PVP from CT and perfusion parameters from DCE-US (B, CVan; each P = nonsignificant). CONCLUSIONS:: Quantitative evaluation of DCE-CT data was feasible in all patients after automated motion correction, whereas DCE-US data could not be quantitatively evaluated in 30% of patients due to respiratory motion and lack of motion correction software. Quantitative arterial perfusion analysis showed moderate significant correlations for blood flow parameters among modalities.

Statistics

Citations

Dimensions.ai Metrics
46 citations in Web of Science®
47 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Oncology and Hematology
04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Radiology, Nuclear Medicine and Imaging
Language:English
Date:2012
Deposited On:21 Nov 2011 13:59
Last Modified:23 Jan 2022 19:35
Publisher:Lippincott Wiliams & Wilkins
ISSN:0020-9996
OA Status:Closed
Publisher DOI:https://doi.org/10.1097/RLI.0b013e318229ff0d
PubMed ID:21788906
Full text not available from this repository.