Header

UZH-Logo

Maintenance Infos

Screening for interstitial lung disease in systemic sclerosis: the diagnostic accuracy of HRCT image series with high increment and reduced number of slices


Winklehner, A; Berger, N; Maurer, B; Distler, O; Alkadhi, H; Frauenfelder, T (2012). Screening for interstitial lung disease in systemic sclerosis: the diagnostic accuracy of HRCT image series with high increment and reduced number of slices. Annals of the Rheumatic Diseases, 71(4):549-552.

Abstract

OBJECTIVES: The objective of this study is to assess diagnostic accuracy for the detection of interstitial lung disease (ILD) in image series with high increment and reduced number of slices in patients with systemic sclerosis (SSc).METHODS: 45 patients with SSc underwent high-resolution CT (HRCT). Three series of secondary captures were reconstructed as follows: series 1, series with 10 mm increment and 1 mm slices; series 2, seven axial images with baso-apical gradient; series 3, three axial images were obtained at the apical, at the level of the carina and basal. The presence and extent of ILD, and the degree of diagnostic confidence were recorded. The effective dose for each image series was estimated. Standard HRCT was the standard of reference.RESULTS: The prevalence of ILD was 55% (25/45). Diagnostic sensitivity and accuracy of series 1, series 2 and series 3 were 100% and 94.4%, 94% and 97.8%, 92% and 97.8%, respectively. The extent of ILD was underestimated in series 3 (p<0.05) and was comparable to the standard HRCT in series 1 and 2 (p>0.05). Estimated dose reduction was more than 90% in all image series.CONCLUSIONS: HRCT image series with low sampling rate allow an accurate detection of ILD with very-low-radiation dose, making this approach potentially valuable for screening in patients with SSc.

Abstract

OBJECTIVES: The objective of this study is to assess diagnostic accuracy for the detection of interstitial lung disease (ILD) in image series with high increment and reduced number of slices in patients with systemic sclerosis (SSc).METHODS: 45 patients with SSc underwent high-resolution CT (HRCT). Three series of secondary captures were reconstructed as follows: series 1, series with 10 mm increment and 1 mm slices; series 2, seven axial images with baso-apical gradient; series 3, three axial images were obtained at the apical, at the level of the carina and basal. The presence and extent of ILD, and the degree of diagnostic confidence were recorded. The effective dose for each image series was estimated. Standard HRCT was the standard of reference.RESULTS: The prevalence of ILD was 55% (25/45). Diagnostic sensitivity and accuracy of series 1, series 2 and series 3 were 100% and 94.4%, 94% and 97.8%, 92% and 97.8%, respectively. The extent of ILD was underestimated in series 3 (p<0.05) and was comparable to the standard HRCT in series 1 and 2 (p>0.05). Estimated dose reduction was more than 90% in all image series.CONCLUSIONS: HRCT image series with low sampling rate allow an accurate detection of ILD with very-low-radiation dose, making this approach potentially valuable for screening in patients with SSc.

Statistics

Citations

Dimensions.ai Metrics
29 citations in Web of Science®
29 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > University Hospital Zurich > Rheumatology Clinic and Institute of Physical Medicine
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Immunology and Allergy
Health Sciences > Rheumatology
Life Sciences > Immunology
Life Sciences > General Biochemistry, Genetics and Molecular Biology
Language:English
Date:2012
Deposited On:20 Dec 2011 12:17
Last Modified:23 Jan 2022 19:49
Publisher:BMJ Publishing Group
ISSN:0003-4967
OA Status:Closed
Publisher DOI:https://doi.org/10.1136/annrheumdis-2011-200564
PubMed ID:22121134
Full text not available from this repository.