3D near-infrared imaging based on a SPAD image sensor


Mata Pavia, J; Niclass, C; Favi, C; Wolf, M; Charbon, E (2011). 3D near-infrared imaging based on a SPAD image sensor. In: International Image Sensor Workshop (IISW), Hokkaido, Japan, 8 June 2011 - 11 June 2011.

Abstract

A new imager for 3D near-infrared imaging has been designed based on a single-photon avalanche diode (SPAD)imager with 128x128 pixels capable of performing time-resolved measurements with a resolution of 97ps. The imager linearity has been improved to make more accurate measurements. A new optical setup has been implemented in order to prove the suitability of this kind of sensors for this application.

Abstract

A new imager for 3D near-infrared imaging has been designed based on a single-photon avalanche diode (SPAD)imager with 128x128 pixels capable of performing time-resolved measurements with a resolution of 97ps. The imager linearity has been improved to make more accurate measurements. A new optical setup has been implemented in order to prove the suitability of this kind of sensors for this application.

Statistics

Downloads

332 downloads since deposited on 06 Mar 2012
7 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Conference or Workshop Item (Speech), refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Neonatology
Dewey Decimal Classification:610 Medicine & health
Language:English
Event End Date:11 June 2011
Deposited On:06 Mar 2012 15:58
Last Modified:30 Jul 2020 03:48
OA Status:Green
Official URL:http://www.imagesensors.org/Current%20Workshop/2011%20Main%20page.htm
Related URLs:http://infoscience.epfl.ch/record/125188/files/Optical3D_v5.pdf