Header

UZH-Logo

Maintenance Infos

The influence of different osteosynthesis configurations with locking compression plates (LCP) on stability and fracture healing after an oblique 45° angle osteotomy


Plecko, Michael; Lagerpusch, Nico; Pegel, Birthe; Andermatt, Daniel; Frigg, Robert; Koch, Rudolf; Sidler, M; Kronen, P; Klein, Karina; Nuss, Katja M; Gedet, Philippe; Bürki, Alexander; Ferguson, Stephen J; Stoeckle, Ulrich; Auer, Jörg A; von Rechenberg, Brigitte (2012). The influence of different osteosynthesis configurations with locking compression plates (LCP) on stability and fracture healing after an oblique 45° angle osteotomy. Injury, 43(7):1041-1051.

Abstract

BACKGROUND:Locking compression plates are used in various configurations with lack of detailed information on consequent bone healing.
STUDY DESIGN:In this in vivo study in sheep 5 different applications of locking compression plate (LCP) were tested using a 45° oblique osteotomy simulating simple fracture pattern. 60 Swiss Alpine sheep where assigned to 5 different groups with 12 sheep each (Group 1: interfragmentary lag screw and an LCP fixed with standard cortex screws as neutralisation plate; Group 2: interfragmentary lag screw and LCP with locking head screws; Group 3: compression plate technique (hybrid construct); Group 4: internal fixator without fracture gap; Group 5: internal fixator with 3mm gap at the osteotomy site). One half of each group (6 sheep) was monitored for 6weeks, and the other half (6 sheep) where followed for 12weeks.
METHODS:X-rays at 3, 6, 9 and 12weeks were performed to monitor the healing process. After sacrifice operated tibiae were tested biomechanically for nondestructive torsion and compared to the tibia of the healthy opposite side. After testing specimens were processed for microradiography, histology, histomorphometry and assessment of calcium deposition by fluorescence microscopy.
RESULTS:In all groups bone healing occurred without complications. Stiffness in biomechanical testing showed a tendency for higher values in G2 but results were not statistically significant. Values for G5 were significantly lower after 6weeks, but after 12weeks values had improved to comparable results. For all groups, except G3, stiffness values improved between 6 and 12weeks. Histomorphometrical data demonstrate endosteal callus to be more marked in G2 at 6weeks.
DISCUSSION AND CONCLUSION:All five configurations resulted in undisturbed bone healing and are considered safe for clinical application.

Abstract

BACKGROUND:Locking compression plates are used in various configurations with lack of detailed information on consequent bone healing.
STUDY DESIGN:In this in vivo study in sheep 5 different applications of locking compression plate (LCP) were tested using a 45° oblique osteotomy simulating simple fracture pattern. 60 Swiss Alpine sheep where assigned to 5 different groups with 12 sheep each (Group 1: interfragmentary lag screw and an LCP fixed with standard cortex screws as neutralisation plate; Group 2: interfragmentary lag screw and LCP with locking head screws; Group 3: compression plate technique (hybrid construct); Group 4: internal fixator without fracture gap; Group 5: internal fixator with 3mm gap at the osteotomy site). One half of each group (6 sheep) was monitored for 6weeks, and the other half (6 sheep) where followed for 12weeks.
METHODS:X-rays at 3, 6, 9 and 12weeks were performed to monitor the healing process. After sacrifice operated tibiae were tested biomechanically for nondestructive torsion and compared to the tibia of the healthy opposite side. After testing specimens were processed for microradiography, histology, histomorphometry and assessment of calcium deposition by fluorescence microscopy.
RESULTS:In all groups bone healing occurred without complications. Stiffness in biomechanical testing showed a tendency for higher values in G2 but results were not statistically significant. Values for G5 were significantly lower after 6weeks, but after 12weeks values had improved to comparable results. For all groups, except G3, stiffness values improved between 6 and 12weeks. Histomorphometrical data demonstrate endosteal callus to be more marked in G2 at 6weeks.
DISCUSSION AND CONCLUSION:All five configurations resulted in undisturbed bone healing and are considered safe for clinical application.

Statistics

Citations

Dimensions.ai Metrics
28 citations in Web of Science®
29 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Department of Trauma Surgery
05 Vetsuisse Faculty > Veterinary Clinic > Equine Department
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Emergency Medicine
Health Sciences > Orthopedics and Sports Medicine
Language:English
Date:2012
Deposited On:07 Mar 2012 10:29
Last Modified:23 Jan 2022 21:09
Publisher:Elsevier
ISSN:0020-1383
OA Status:Closed
Publisher DOI:https://doi.org/10.1016/j.injury.2011.12.016
PubMed ID:22284334
Full text not available from this repository.