Header

UZH-Logo

Maintenance Infos

Adhesion of conventional and simplified resin-based luting cements to superficial and deep dentin


Özcan, Mutlu; Mese, Ayse (2012). Adhesion of conventional and simplified resin-based luting cements to superficial and deep dentin. Clinical Oral Investigations, 4(16):1081-1088.

Abstract

This study evaluated the bond strengths of conventional (chemically and dual-polymerized) and simplified resin-based luting cements with their corresponding adhesives to superficial dentin (SD) and deep dentin (DD). Recently extracted third molars (N = 70, n = 10 per group) were obtained and prepared for testing procedures. After using their corresponding etchants, primers, and/or adhesive systems, the conventional and simplified cements (Variolink II [group A, conventional], Bifix QM [group B, conventional], Panavia F2.0 [group C, conventional], Multilink Automix [group D, simplified], Superbond C&B [group E, conventional], Clearfil Esthetic Cement [group F, simplified], Ketac-Fil [group G, conventional]) were adhered incrementally onto the dentin surfaces using polyethylene molds (inner diameter 3.5 mm, height 5 mm) and polymerized accordingly. Resin-modified glass-ionomer cement (RMGIC) acted as the control material. Shear bond strengths (1 mm/min) were determined after 500 times of thermocycling. Kruskal-Wallis and Mann-Whitney tests were used to analyze the data (α = 0.05). Bond strength (MPa) results were significantly affected by the cement types and their corresponding adhesive systems (p ≤ 0.05). The shear bond strengths (MPa ± SD) for groups A-G were 14.6 ± 3.8, 18.9 ± 3.9, 5.5 ± 4.5, 3.1 ± 3.6, 1.1 ± 2.5, 15.5 ± 2.6, 7 ± 4.3 and 7.1 ± 5.8, 15.1 ± 7.8, 8.4 ± 7.3, 7.5 ± 7.3, 4.9 ± 5.1, 12.5 ± 2.1, 6 ± 2.6 for SD and DD, respectively. The level of dentin depth did not decrease the bond strength significantly (p > 0.05) for all cements, except for Variolink II (p < 0.05). On the SD, bond strength of resin cements with "etch-and-rinse" adhesive systems (Variolink II, Bifix QM, Super-Bond C&B) showed similar results being higher than those of the simplified ones. Simplified cements and RMGIC as control material showed inferior adhesion to superficial and deep dentin compared to conventional resin cements tested.

Abstract

This study evaluated the bond strengths of conventional (chemically and dual-polymerized) and simplified resin-based luting cements with their corresponding adhesives to superficial dentin (SD) and deep dentin (DD). Recently extracted third molars (N = 70, n = 10 per group) were obtained and prepared for testing procedures. After using their corresponding etchants, primers, and/or adhesive systems, the conventional and simplified cements (Variolink II [group A, conventional], Bifix QM [group B, conventional], Panavia F2.0 [group C, conventional], Multilink Automix [group D, simplified], Superbond C&B [group E, conventional], Clearfil Esthetic Cement [group F, simplified], Ketac-Fil [group G, conventional]) were adhered incrementally onto the dentin surfaces using polyethylene molds (inner diameter 3.5 mm, height 5 mm) and polymerized accordingly. Resin-modified glass-ionomer cement (RMGIC) acted as the control material. Shear bond strengths (1 mm/min) were determined after 500 times of thermocycling. Kruskal-Wallis and Mann-Whitney tests were used to analyze the data (α = 0.05). Bond strength (MPa) results were significantly affected by the cement types and their corresponding adhesive systems (p ≤ 0.05). The shear bond strengths (MPa ± SD) for groups A-G were 14.6 ± 3.8, 18.9 ± 3.9, 5.5 ± 4.5, 3.1 ± 3.6, 1.1 ± 2.5, 15.5 ± 2.6, 7 ± 4.3 and 7.1 ± 5.8, 15.1 ± 7.8, 8.4 ± 7.3, 7.5 ± 7.3, 4.9 ± 5.1, 12.5 ± 2.1, 6 ± 2.6 for SD and DD, respectively. The level of dentin depth did not decrease the bond strength significantly (p > 0.05) for all cements, except for Variolink II (p < 0.05). On the SD, bond strength of resin cements with "etch-and-rinse" adhesive systems (Variolink II, Bifix QM, Super-Bond C&B) showed similar results being higher than those of the simplified ones. Simplified cements and RMGIC as control material showed inferior adhesion to superficial and deep dentin compared to conventional resin cements tested.

Statistics

Citations

Dimensions.ai Metrics
26 citations in Web of Science®
28 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

799 downloads since deposited on 20 Jul 2012
28 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Reconstructive Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > General Dentistry
Language:English
Date:2012
Deposited On:20 Jul 2012 10:45
Last Modified:23 Jan 2022 21:58
Publisher:Springer
ISSN:1432-6981
OA Status:Green
Publisher DOI:https://doi.org/10.1007/s00784-011-0594-z
PubMed ID:21833482
  • Content: Accepted Version
  • Content: Published Version
  • Language: English
  • Description: Nationallizenz 142-005