Navigation auf zora.uzh.ch

Search

ZORA (Zurich Open Repository and Archive)

Quantification of myocardial blood flow with 82Rb positron emission tomography: clinical validation with 15O-water

Prior, John O; Allenbach, Gilles; Valenta, Ines; Kosinski, Marek; Burger, Cyrill; Verdun, Francis R; Bischof Delaloye, Angelika; Kaufmann, Philipp A (2012). Quantification of myocardial blood flow with 82Rb positron emission tomography: clinical validation with 15O-water. European Journal of Nuclear Medicine and Molecular Imaging, 39(6):1037-1047.

Abstract

PURPOSE:
Quantification of myocardial blood flow (MBF) with generator-produced (82)Rb is an attractive alternative for centres without an on-site cyclotron. Our aim was to validate (82)Rb-measured MBF in relation to that measured using (15)O-water, as a tracer 100% of which can be extracted from the circulation even at high flow rates, in healthy control subject and patients with mild coronary artery disease (CAD).
METHODS:
MBF was measured at rest and during adenosine-induced hyperaemia with (82)Rb and (15)O-water PET in 33 participants (22 control subjects, aged 30 ± 13 years; 11 CAD patients without transmural infarction, aged 60 ± 13 years). A one-tissue compartment (82)Rb model with ventricular spillover correction was used. The (82)Rb flow-dependent extraction rate was derived from (15)O-water measurements in a subset of 11 control subjects. Myocardial flow reserve (MFR) was defined as the hyperaemic/rest MBF. Pearson's correlation r, Bland-Altman 95% limits of agreement (LoA), and Lin's concordance correlation ρ (c) (measuring both precision and accuracy) were used.
RESULTS:
Over the entire MBF range (0.66-4.7 ml/min/g), concordance was excellent for MBF (r = 0.90, [(82)Rb-(15)O-water] mean difference ± SD = 0.04 ± 0.66 ml/min/g, LoA = -1.26 to 1.33 ml/min/g, ρ(c) = 0.88) and MFR (range 1.79-5.81, r = 0.83, mean difference = 0.14 ± 0.58, LoA = -0.99 to 1.28, ρ(c) = 0.82). Hyperaemic MBF was reduced in CAD patients compared with the subset of 11 control subjects (2.53 ± 0.74 vs. 3.62 ± 0.68 ml/min/g, p = 0.002, for (15)O-water; 2.53 ± 1.01 vs. 3.82 ± 1.21 ml/min/g, p = 0.013, for (82)Rb) and this was paralleled by a lower MFR (2.65 ± 0.62 vs. 3.79 ± 0.98, p = 0.004, for (15)O-water; 2.85 ± 0.91 vs. 3.88 ± 0.91, p = 0.012, for (82)Rb). Myocardial perfusion was homogeneous in 1,114 of 1,122 segments (99.3%) and there were no differences in MBF among the coronary artery territories (p > 0.31).
CONCLUSION:
Quantification of MBF with (82)Rb with a newly derived correction for the nonlinear extraction function was validated against MBF measured using (15)O-water in control subjects and patients with mild CAD, where it was found to be accurate at high flow rates. (82)Rb-derived MBF estimates seem robust for clinical research, advancing a step further towards its implementation in clinical routine.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Clinic for Nuclear Medicine
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Radiology, Nuclear Medicine and Imaging
Language:English
Date:8 March 2012
Deposited On:18 Jul 2012 07:27
Last Modified:07 Sep 2024 01:38
Publisher:Springer
ISSN:1619-7070
OA Status:Hybrid
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1007/s00259-012-2082-3
PubMed ID:22398957
Download PDF  'Quantification of myocardial blood flow with 82Rb positron emission tomography: clinical validation with 15O-water'.
Preview
  • Content: Published Version

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
79 citations in Web of Science®
77 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

0 downloads since deposited on 18 Jul 2012
9 downloads since 12 months

Authors, Affiliations, Collaborations

Similar Publications