Header

UZH-Logo

Maintenance Infos

Smad8/BMP2-engineered mesenchymal stem cells induce accelerated recovery of the biomechanical properties of the Achilles tendon


Pelled, Gadi; Snedeker, Jess G; Ben-Arav, Ayelet; Rigozzi, Samuela; Zilberman, Yoram; Kimelman-Bleich, Nadav; Gazit, Zulma; Müller, Ralph; Gazit, Dan (2012). Smad8/BMP2-engineered mesenchymal stem cells induce accelerated recovery of the biomechanical properties of the Achilles tendon. Journal of Orthopaedic Research, 30(12):1932-1939.

Abstract

Tendon tissue regeneration is an important goal for orthopedic medicine. We hypothesized that implantation of Smad8/BMP2-engineered MSCs in a full-thickness defect of the Achilles tendon (AT) would induce regeneration of tissue with improved biomechanical properties. A 2 mm defect was created in the distal region of murine ATs. The injured tendons were then sutured together or given implants of genetically engineered MSCs (GE group), non-engineered MSCs (CH3 group), or fibrin gel containing no cells (FG group). Three weeks later the mice were killed, and their healing tendons were excised and processed for histological or biomechanical analysis. A biomechanical analysis showed that tendons that received implants of genetically engineered MSCs had the highest effective stiffness (>70% greater than natural healing, p < 0.001) and elastic modulus. There were no significant differences in either ultimate load or maximum stress among the treatment groups. Histological analysis revealed a tendon-like structure with elongated cells mainly in the GE group. ATs that had been implanted with Smad8/BMP2-engineered stem cells displayed a better material distribution and functional recovery than control groups. While additional study is required to determine long-term effects of GE MSCs on tendon healing, we conclude that genetically engineered MSCs may be a promising therapeutic tool for accelerating short-term functional recovery in the treatment of tendon injuries.

Abstract

Tendon tissue regeneration is an important goal for orthopedic medicine. We hypothesized that implantation of Smad8/BMP2-engineered MSCs in a full-thickness defect of the Achilles tendon (AT) would induce regeneration of tissue with improved biomechanical properties. A 2 mm defect was created in the distal region of murine ATs. The injured tendons were then sutured together or given implants of genetically engineered MSCs (GE group), non-engineered MSCs (CH3 group), or fibrin gel containing no cells (FG group). Three weeks later the mice were killed, and their healing tendons were excised and processed for histological or biomechanical analysis. A biomechanical analysis showed that tendons that received implants of genetically engineered MSCs had the highest effective stiffness (>70% greater than natural healing, p < 0.001) and elastic modulus. There were no significant differences in either ultimate load or maximum stress among the treatment groups. Histological analysis revealed a tendon-like structure with elongated cells mainly in the GE group. ATs that had been implanted with Smad8/BMP2-engineered stem cells displayed a better material distribution and functional recovery than control groups. While additional study is required to determine long-term effects of GE MSCs on tendon healing, we conclude that genetically engineered MSCs may be a promising therapeutic tool for accelerating short-term functional recovery in the treatment of tendon injuries.

Statistics

Citations

Dimensions.ai Metrics
34 citations in Web of Science®
35 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 18 Jan 2013
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Orthopedics and Sports Medicine
Uncontrolled Keywords:Orthopedics and Sports Medicine
Language:English
Date:2012
Deposited On:18 Jan 2013 09:15
Last Modified:23 Jan 2022 23:30
Publisher:Wiley-Blackwell
ISSN:0736-0266
OA Status:Closed
Publisher DOI:https://doi.org/10.1002/jor.22167
PubMed ID:22696396