Controlled laboratory testing of arthroscopic shaver systems: do blades, contact pressure, and speed influence their performance?


Wieser, Karl; Erschbamer, Matthias; Neuhofer, Stefan; Ek, Eugene T; Gerber, Christian; Meyer, Dominik C (2012). Controlled laboratory testing of arthroscopic shaver systems: do blades, contact pressure, and speed influence their performance? Arthroscopy: The Journal of Arthroscopic & Related Surgery, 28(10):1497-1503.

Abstract

PURPOSE: The purposes of this study were (1) to establish a reproducible, standardized testing protocol to evaluate the performance of different shaver systems and blades in a controlled, laboratory setting, and (2) to determine the optimal use of different blades with respect to the influence of contact pressure and speed of blade rotation. METHOD: A holding device was developed for reproducible testing of soft-tissue (tendon and meniscal) resection performance in a submerged environment, after loading of the shaver with interchangeable weights. The Karl Storz Powershaver S2 (Karl Storz, Tuttlingen, Germany), the Stryker Power Shaver System (Stryker, Kalamazoo, MI), and the Dyonics Power Shaver System (Smith & Nephew, Andover, MA) were tested, with different 5.5-mm shaver blades and varied contact pressure and rotation speed. For quality testing, serrated shaver blades were evaluated at 40× image magnification. Overall, more than 150 test cycles were performed. RESULTS: No significant differences could be detected between comparable blade types from different manufacturers. Shavers with a serrated inner blade and smooth outer blade performed significantly better than the standard smooth resectors (P < .001). Teeth on the outer layer of the blade did not lead to any further improvement of resection (P = .482). Optimal contact pressure ranged between 6 and 8 N, and optimal speed was found to be 2,000 to 2,500 rpm. Minimal blunting of the shaver blades occurred after soft-tissue resection; however, with bone resection, progressive blunting of the shaver blades was observed. CONCLUSIONS: Arthroscopic shavers can be tested in a controlled setting. The performance of the tested shaver types appears to be fairly independent of the manufacturer. For tendon resection, a smooth outer blade and serrated inner blade were optimal. CLINICAL RELEVANCE: This is one of the first established independent and quantitative assessments of arthroscopic shaver systems and blades. We believe that this study will assist the surgeon in choosing the optimal tool for the desired effect.

Abstract

PURPOSE: The purposes of this study were (1) to establish a reproducible, standardized testing protocol to evaluate the performance of different shaver systems and blades in a controlled, laboratory setting, and (2) to determine the optimal use of different blades with respect to the influence of contact pressure and speed of blade rotation. METHOD: A holding device was developed for reproducible testing of soft-tissue (tendon and meniscal) resection performance in a submerged environment, after loading of the shaver with interchangeable weights. The Karl Storz Powershaver S2 (Karl Storz, Tuttlingen, Germany), the Stryker Power Shaver System (Stryker, Kalamazoo, MI), and the Dyonics Power Shaver System (Smith & Nephew, Andover, MA) were tested, with different 5.5-mm shaver blades and varied contact pressure and rotation speed. For quality testing, serrated shaver blades were evaluated at 40× image magnification. Overall, more than 150 test cycles were performed. RESULTS: No significant differences could be detected between comparable blade types from different manufacturers. Shavers with a serrated inner blade and smooth outer blade performed significantly better than the standard smooth resectors (P < .001). Teeth on the outer layer of the blade did not lead to any further improvement of resection (P = .482). Optimal contact pressure ranged between 6 and 8 N, and optimal speed was found to be 2,000 to 2,500 rpm. Minimal blunting of the shaver blades occurred after soft-tissue resection; however, with bone resection, progressive blunting of the shaver blades was observed. CONCLUSIONS: Arthroscopic shavers can be tested in a controlled setting. The performance of the tested shaver types appears to be fairly independent of the manufacturer. For tendon resection, a smooth outer blade and serrated inner blade were optimal. CLINICAL RELEVANCE: This is one of the first established independent and quantitative assessments of arthroscopic shaver systems and blades. We believe that this study will assist the surgeon in choosing the optimal tool for the desired effect.

Statistics

Citations

Dimensions.ai Metrics
4 citations in Web of Science®
7 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Balgrist University Hospital, Swiss Spinal Cord Injury Center
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Orthopedics and Sports Medicine
Language:English
Date:November 2012
Deposited On:31 Jan 2013 09:48
Last Modified:23 Jan 2022 23:42
Publisher:Elsevier
ISSN:0749-8063
OA Status:Closed
Publisher DOI:https://doi.org/10.1016/j.arthro.2012.03.006
PubMed ID:22683374
Full text not available from this repository.