Cardiac proton spectroscopy using large coil arrays


Weiss, Kilian; Martini, Nicola; Boesiger, Peter; Kozerke, Sebastian (2013). Cardiac proton spectroscopy using large coil arrays. NMR in Biomedicine, 26(3):276-284.

Abstract

Large coil arrays are widely used in clinical routine for cardiovascular imaging providing extended spatial coverage and enabling accelerated acquisition using parallel imaging approaches. This work investigates the use of large coil arrays in single-voxel cardiac spectroscopy for the detection of myocardial creatine and triglyceride content. For this purpose, a navigator-gated and cardiac-triggered point-resolved spectroscopy sequence was implemented, and data obtained in 11 healthy volunteers using 32- and 5-element coil arrays were compared. For combination of the individual coil element signals, four strategies were evaluated differing in the manner of estimation of the complex coil weights and the amount of additional information required for coil combination. In all volunteers, and with both the 32- and 5-channel coil arrays, triglyceride-to-water (0.44 ± 0.19% and 0.45 ± 0.17%) and total creatine-to-water (0.05 ± 0.02% and 0.05 ± 0.01%) contents were computed. The values were found to agree well, showing an intraclass correlation coefficient of 0.76 (p < 0.003). The results revealed a gain in signal-to-noise ratio of approximately 24% with the 32-channel coil relative to the 5-channel array. The findings may foster the integration of cardiac spectroscopy into clinical practice using large coil arrays, provided that appropriate reconstruction algorithms are implemented.

Abstract

Large coil arrays are widely used in clinical routine for cardiovascular imaging providing extended spatial coverage and enabling accelerated acquisition using parallel imaging approaches. This work investigates the use of large coil arrays in single-voxel cardiac spectroscopy for the detection of myocardial creatine and triglyceride content. For this purpose, a navigator-gated and cardiac-triggered point-resolved spectroscopy sequence was implemented, and data obtained in 11 healthy volunteers using 32- and 5-element coil arrays were compared. For combination of the individual coil element signals, four strategies were evaluated differing in the manner of estimation of the complex coil weights and the amount of additional information required for coil combination. In all volunteers, and with both the 32- and 5-channel coil arrays, triglyceride-to-water (0.44 ± 0.19% and 0.45 ± 0.17%) and total creatine-to-water (0.05 ± 0.02% and 0.05 ± 0.01%) contents were computed. The values were found to agree well, showing an intraclass correlation coefficient of 0.76 (p < 0.003). The results revealed a gain in signal-to-noise ratio of approximately 24% with the 32-channel coil relative to the 5-channel array. The findings may foster the integration of cardiac spectroscopy into clinical practice using large coil arrays, provided that appropriate reconstruction algorithms are implemented.

Statistics

Citations

Dimensions.ai Metrics
19 citations in Web of Science®
19 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Institute of Biomedical Engineering
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Scopus Subject Areas:Life Sciences > Molecular Medicine
Health Sciences > Radiology, Nuclear Medicine and Imaging
Physical Sciences > Spectroscopy
Uncontrolled Keywords:Spectroscopy, Molecular Medicine, Radiology Nuclear Medicine and imaging
Language:English
Date:2013
Deposited On:14 Feb 2013 09:55
Last Modified:09 Nov 2023 02:41
Publisher:Wiley-Blackwell
ISSN:0952-3480
OA Status:Closed
Publisher DOI:https://doi.org/10.1002/nbm.2845
PubMed ID:22933454
Full text not available from this repository.