Navigation auf zora.uzh.ch

Search

ZORA (Zurich Open Repository and Archive)

Osseointegration and biocompatibility of different metal implants--a comparative experimental investigation in sheep

Plecko, Michael; Sievert, Christine; Andermatt, Daniel; Frigg, Robert; Kronen, P; Klein, Karina; Stübinger, Stefan; Nuss, K; Bürki, Alexander; Ferguson, Stephen; Stoeckle, Ulrich; von Rechenberg, Brigitte (2012). Osseointegration and biocompatibility of different metal implants--a comparative experimental investigation in sheep. BMC Musculoskeletal Disorders, 13:32.

Abstract

BACKGROUND: In the present study, 4 different metallic implant materials, either partly coated or polished, were tested for their osseointegration and biocompatibility in a pelvic implantation model in sheep.
METHODS: Materials to be evaluated were: Cobalt-Chrome (CC), Cobalt-Chrome/Titanium coating (CCTC), Cobalt-Chrome/Zirconium/Titanium coating (CCZTC), Pure Titanium Standard (PTST), Steel, TAN Standard (TANST) and TAN new finish (TANNEW). Surgery was performed on 7 sheep, with 18 implants per sheep, for a total of 63 implants. After 8 weeks, the specimens were harvested and evaluated macroscopically, radiologically, biomechanically (removal torque), histomorphometrically and histologically.
RESULTS: Cobalt-Chrome screws showed significantly (p = 0.031) lower removal torque values than pure titanium screws and also a tendency towards lower values compared to the other materials, except for steel. Steel screws showed no significant differences, in comparison to cobalt-chrome and TANST, however also a trend towards lower torque values than the remaining materials. The results of the fluorescence sections agreed with those of the biomechanical test. Histomorphometrically, there were no significant differences of bone area between the groups. The BIC (bone-to-implant-contact), used for the assessment of the osseointegration, was significantly lower for cobalt-chrome, compared to steel (p = 0.001). Steel again showed a lower ratio (p = 0.0001) compared to the other materials.
CONCLUSION: This study demonstrated that cobalt-chrome and steel show less osseointegration than the other metals and metal-alloys. However, osseointegration of cobalt-chrome was improved by zirconium and/or titanium based coatings (CCTC, TANST, TAN, TANNEW) being similar as pure titanium in their osseointegrative behavior.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Department of Trauma Surgery
05 Vetsuisse Faculty > Veterinary Clinic > Equine Department
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Rheumatology
Health Sciences > Orthopedics and Sports Medicine
Language:English
Date:2012
Deposited On:21 Feb 2013 13:44
Last Modified:09 Sep 2024 01:36
Publisher:BioMed Central
ISSN:1471-2474
OA Status:Gold
Free access at:PubMed ID. An embargo period may apply.
Publisher DOI:https://doi.org/10.1186/1471-2474-13-32
PubMed ID:22400715
Download PDF  'Osseointegration and biocompatibility of different metal implants--a comparative experimental investigation in sheep'.
Preview
  • Content: Published Version
  • Language: English
  • Licence: Creative Commons: Attribution 2.0 Generic (CC BY 2.0)

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
79 citations in Web of Science®
92 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

170 downloads since deposited on 21 Feb 2013
10 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications