Header

UZH-Logo

Maintenance Infos

Effect of rapid fluid resuscitation using crystalloids or colloids on hemostasis in piglets


Mauch, J; Madjdpour, C; Kutter, Annette P N; Spielmann, N; Bettschart-Wolfensberger, Regula; Weiss, M; Haas, T (2013). Effect of rapid fluid resuscitation using crystalloids or colloids on hemostasis in piglets. Paediatric Anaesthesia, 23(3):258-264.

Abstract

BACKGROUND AND OBJECTIVES: Impairment of blood coagulation is one of the main side effects of volume replacement, particularly if artificial colloids such as hydroxyethyl starch (HES) and gelatine preparations are used. This animal study aimed to evaluate the effect of a single fast intravenous crystalloid or colloid fluid bolus on blood coagulation as measured by rotation thromboelastometry (ROTEM).
METHODS: Thirty-two anesthetized piglets were infused with a rapid 20 ml·kg(-1) fluid bolus of either normal saline (NS), 4% gelatine, 5% albumin or 6% HES 130/0.4 (n = 8 per group) over a period of 2 min. Hemostasis was assessed by ROTEM before and 1 min after fluid administration. Within-group differences were analyzed by Wilcoxon test, and additionally overall Kruskal-Wallis test followed by posthoc Mann-Whitney U-test were applied to detect differences between groups.
RESULTS: All fluids caused a significant weakening of clot strength within groups. HES and gelatine showed a significantly stronger impairment of clot growth and maximum clot firmness as compared with albumin and normal saline. Impairment of fibrin polymerization was more pronounced following HES as compared with all other fluids.
CONCLUSION: After moderate but very fast volume loading, HES and gelatine impair blood coagulation to a larger extent as compared with albumin or normal saline, while no significant differences were observed between both artificial colloids.

Abstract

BACKGROUND AND OBJECTIVES: Impairment of blood coagulation is one of the main side effects of volume replacement, particularly if artificial colloids such as hydroxyethyl starch (HES) and gelatine preparations are used. This animal study aimed to evaluate the effect of a single fast intravenous crystalloid or colloid fluid bolus on blood coagulation as measured by rotation thromboelastometry (ROTEM).
METHODS: Thirty-two anesthetized piglets were infused with a rapid 20 ml·kg(-1) fluid bolus of either normal saline (NS), 4% gelatine, 5% albumin or 6% HES 130/0.4 (n = 8 per group) over a period of 2 min. Hemostasis was assessed by ROTEM before and 1 min after fluid administration. Within-group differences were analyzed by Wilcoxon test, and additionally overall Kruskal-Wallis test followed by posthoc Mann-Whitney U-test were applied to detect differences between groups.
RESULTS: All fluids caused a significant weakening of clot strength within groups. HES and gelatine showed a significantly stronger impairment of clot growth and maximum clot firmness as compared with albumin and normal saline. Impairment of fibrin polymerization was more pronounced following HES as compared with all other fluids.
CONCLUSION: After moderate but very fast volume loading, HES and gelatine impair blood coagulation to a larger extent as compared with albumin or normal saline, while no significant differences were observed between both artificial colloids.

Statistics

Citations

Dimensions.ai Metrics
21 citations in Web of Science®
21 citations in Scopus®
Google Scholar™

Altmetrics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Children's Hospital Zurich > Clinic for Surgery
05 Vetsuisse Faculty > Veterinary Clinic > Equine Department
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Pediatrics, Perinatology and Child Health
Health Sciences > Anesthesiology and Pain Medicine
Language:English
Date:2013
Deposited On:22 Mar 2013 15:46
Last Modified:24 Jan 2022 00:16
Publisher:Wiley-Blackwell
ISSN:1155-5645
OA Status:Closed
Publisher DOI:https://doi.org/10.1111/pan.12106
PubMed ID:23279083
Full text not available from this repository.