Does the ultrasonic cleaning medium affect the adhesion of resin cement to feldspathic ceramic?


Martins, Maria Elizabeth; Leite, Fabíola Pessoa; Queiroz, José Renato; Vanderlei, Aleska Dias; Reskalla, Helcio Nagib; Özcan, Mutlu (2012). Does the ultrasonic cleaning medium affect the adhesion of resin cement to feldspathic ceramic? Journal of Adhesive Dentistry, 14(6):507-509.

Abstract

PURPOSE: To evaluate the effect of different cleaning media on the adhesion of resin cement to feldspathic ceramic after etching.
MATERIALS AND METHODS: The cementation surfaces of ceramic blocks (N = 20, n = 5 per group) were etched with 10% hydrofluoric acid (HF) gel for 20 s and rinsed for 60 s. They were then randomly assigned to 4 groups: G1: air-water spray+drying (control); G2: ultrasonic cleaning in distilled water for 4 min+drying; G3: ultrasonic cleaning in 99.5% acetone for 4 min+drying; G4: ultrasonic cleaning in 70% alcohol for 4 min+drying. The ceramic blocks were silanized and cemented (RelyX ARC) to the composite blocks. Subsequently, the microtensile bond strength test (µTBS) was performed. In addition, EDS analysis was made to assess the elemental composition of the conditioned and cleaned ceramic surfaces.
RESULTS: A significantly higher mean µTBS was obtained when specimens had been ultrasonically cleaned in distilled water (G2: 18.8 ± 0.4 MPa) (p < 0.05) compared to other groups (G1: 16.6 ± 0.5; G3: 16.1 ± 0.9; G4: 15.8 ± 1.4) (one-way ANOVA). EDS analysis indicated the presence of F- only in G1. Dissolved precipitates after HF etching were removed by ultrasonic cleaning.
CONCLUSION: Cleaning the HF-etched ceramic surface ultrasonically in distilled water is recommended, instead of rinsing it with air-water spray only.

Abstract

PURPOSE: To evaluate the effect of different cleaning media on the adhesion of resin cement to feldspathic ceramic after etching.
MATERIALS AND METHODS: The cementation surfaces of ceramic blocks (N = 20, n = 5 per group) were etched with 10% hydrofluoric acid (HF) gel for 20 s and rinsed for 60 s. They were then randomly assigned to 4 groups: G1: air-water spray+drying (control); G2: ultrasonic cleaning in distilled water for 4 min+drying; G3: ultrasonic cleaning in 99.5% acetone for 4 min+drying; G4: ultrasonic cleaning in 70% alcohol for 4 min+drying. The ceramic blocks were silanized and cemented (RelyX ARC) to the composite blocks. Subsequently, the microtensile bond strength test (µTBS) was performed. In addition, EDS analysis was made to assess the elemental composition of the conditioned and cleaned ceramic surfaces.
RESULTS: A significantly higher mean µTBS was obtained when specimens had been ultrasonically cleaned in distilled water (G2: 18.8 ± 0.4 MPa) (p < 0.05) compared to other groups (G1: 16.6 ± 0.5; G3: 16.1 ± 0.9; G4: 15.8 ± 1.4) (one-way ANOVA). EDS analysis indicated the presence of F- only in G1. Dissolved precipitates after HF etching were removed by ultrasonic cleaning.
CONCLUSION: Cleaning the HF-etched ceramic surface ultrasonically in distilled water is recommended, instead of rinsing it with air-water spray only.

Statistics

Citations

Dimensions.ai Metrics
15 citations in Web of Science®
18 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

2 downloads since deposited on 07 Mar 2013
0 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Reconstructive Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Orthodontics
Health Sciences > Oral Surgery
Health Sciences > Periodontics
Language:English
Date:2012
Deposited On:07 Mar 2013 12:34
Last Modified:23 Mar 2023 09:24
Publisher:Quintessence Publishing
ISSN:1461-5185
OA Status:Closed
Publisher DOI:https://doi.org/10.3290/j.jad.a28625
PubMed ID:23240109