Navigation auf zora.uzh.ch

Search

ZORA (Zurich Open Repository and Archive)

Assessing lung transplantation ischemia-reperfusion injury by microcomputed tomography and ultrashort echo-time magnetic resonance imaging in a mouse model

Wurnig, Moritz C; Tsushima, Yukio; Weiger, Markus; Jungraithmayr, Wolfgang; Boss, Andreas (2014). Assessing lung transplantation ischemia-reperfusion injury by microcomputed tomography and ultrashort echo-time magnetic resonance imaging in a mouse model. Investigative Radiology, 49(1):23-28.

Abstract

PURPOSE: Ischemia-reperfusion injury (I/R) is a common early complication after lung transplantation. The purpose of this study was to compare ultrashort echo-time (UTE) sequences in magnetic resonance imaging (MRI) with a microcomputed tomography (micro-CT) reference standard for detection of I/R injury in a lung transplantation mouse model. MATERIALS AND METHODS: Six mice (C57BL/6) underwent orthotopic lung transplantation using donor grafts that were exposed to 6-hour cold ischemia. Imaging was performed within 24 hours after the transplantation with high-resolution micro-CT (tube voltage, 50 kV; current, 500 mA; aluminum filter, 0.5 mm; voxel size, 35 × 35 × 35 μm) and small-animal MRI at 4.7 T with a linearly polarized whole-body mouse coil. The imaging protocol comprised radial 3-dimensional UTE sequences with different echo times (repetition time, 8 milliseconds; echo time, 50/75/100/500/1500/3000/4000/5000 μs; voxel size, 350 × 350 × 350 μm). Images were assessed visually and through calculation of contrast-to-noise ratio (CNR) values. Calculated S0 values and T2* transverse relaxation times (MRI) of lung parenchyma were compared with Hounsfield unit (HU) density in micro-CT images. Receiver operating characteristic curves and area under the curve values were calculated for comparison of diagnostic power. All samples underwent a histologic examination. RESULTS: The results of both UTE MRI and micro-CT showed an excellent depiction of pulmonary infiltration due to I/R injury, with MRI exhibiting a significantly higher CNR (mean [SD] CNR MRI, 19.7 [8.0]; mean [SD] CNR micro-CT, 10.3 [2.5]; P < 0.001). Measured parametrical values were as follows: mean (SD) HU, -416 (120); mean (SD) S0 value, 1655 (440); mean (SD) T2*, 895 (870) μs for the non-transplanted right lung and mean (SD) HU, 29 (35); mean (SD) S0 value, 2310 (300); and mean (SD) T2*, 4550 (3230) μs for the transplanted left lung. Slight infiltration could be better discriminated with micro-CT, whereas, in strong infiltration, a better contrast was provided by UTE MRI. The area under the curve values resulting from the receiver operating characteristic curve analysis were 0.99 for HU density, 0.89 for S0, 0.96 for T2*, and 0.98 for the combination of S0 and T2*. CONCLUSIONS: Results show that MRI of the lung has a similar diagnostic power compared with that of micro-CT regarding the detection of I/R injury after experimental lung transplantation. Both modalities provide complementary information in the assessment of dense and slight infiltration in the early phase after lung transplantation. Therefore, UTE MRI seems to be a promising addition to computed tomographic imaging in the assessment of I/R injury after lung transplantation.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Division of Surgical Research
04 Faculty of Medicine > University Hospital Zurich > Clinic for Diagnostic and Interventional Radiology
04 Faculty of Medicine > Institute of Biomedical Engineering
04 Faculty of Medicine > University Hospital Zurich > Clinic for Thoracic Surgery
Dewey Decimal Classification:170 Ethics
610 Medicine & health
Scopus Subject Areas:Health Sciences > Radiology, Nuclear Medicine and Imaging
Language:English
Date:2014
Deposited On:25 Sep 2013 15:05
Last Modified:09 Sep 2024 01:40
Publisher:Lippincott, Williams & Wilkins
ISSN:0020-9996
OA Status:Green
Publisher DOI:https://doi.org/10.1097/RLI.0b013e3182a53111
PubMed ID:24056111
Download PDF  'Assessing lung transplantation ischemia-reperfusion injury by microcomputed tomography and ultrashort echo-time magnetic resonance imaging in a mouse model'.
Preview
  • Content: Published Version

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
16 citations in Web of Science®
17 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

148 downloads since deposited on 25 Sep 2013
19 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications