Navigation auf zora.uzh.ch

Search ZORA

ZORA (Zurich Open Repository and Archive)

Evaluation of two dental registration-splint techniques for surgical navigation in cranio-maxillofacial surgery

Venosta, Dominik; Sun, Yi; Matthews, Felix; Kruse, Astrid L; Lanzer, Martin; Gander, Thomas; Grätz, Klaus W; Lübbers, Heinz-Theo (2014). Evaluation of two dental registration-splint techniques for surgical navigation in cranio-maxillofacial surgery. Journal of Cranio-Maxillofacial Surgery, 42(5):448-453.

Abstract

BACKGROUND: Surgical navigation requires precise registration of the pre-operative image dataset to the patient in the operation theatre. Different marker-based and marker-free registration techniques are available, each of them with advantages and disadvantages regarding precision and clinical handling. In this model study, the precision of two dental splint techniques for marker-based registration is analyzed. MATERIALS AND METHODS: A synthetic full-size human skull was registered with its cone beam computed tomography dataset using (a) a dentally-mounted "rapid" occlusal splint with five titanium screws directly attached to the splint, (b) an "extender", a dentally-mounted occlusal splint with similar fiducials fixed to an extension of the splint. The target registration error was measured for 170 landmarks distributed over the viscero- and neurocranium in 10 repeats per splint type using the Vector Vision(2) (BrainLAB AG, Heimstetten, Germany) navigation system. Statistical and graphical evaluations were performed per anatomical region. RESULTS: In the periorbital region, the rapid splint, with an average deviation of 1.50 mm (SD = 0.439) showed greater accuracy than the extender with 1.76 mm (SD = 0.525). The viscerocranial results for both splints were similar (extender 1.84 mm, SD = 0.559, rapid occlusal splint 1.86 mm, SD = 0.686). In the cranial vault region, registration with the extender (2.33 mm, SD = 0.685) proved to be more precise than with the rapid splint (2.86 mm, SD = 0.929). CONCLUSIONS: Due to the more compact dimension of the rapid occlusal splint, errors close to the splint were smaller compared to the extender technique. The advantage of greater distances between the registration fiducials on the extender is particularly important in areas such as the orbital roof, the cranial vault, and the lateral skull base.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Cranio-Maxillofacial Surgery
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > Surgery
Health Sciences > Oral Surgery
Health Sciences > Otorhinolaryngology
Language:English
Date:2014
Deposited On:29 Nov 2013 13:05
Last Modified:10 May 2025 01:36
Publisher:Elsevier
ISSN:1010-5182
OA Status:Green
Publisher DOI:https://doi.org/10.1016/j.jcms.2013.05.040
PubMed ID:23835568

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
22 citations in Web of Science®
27 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

205 downloads since deposited on 29 Nov 2013
35 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications