Header

UZH-Logo

Maintenance Infos

Influence of plasma pretreatment on shear bond strength of self-adhesive resin cements to polyetheretherketone


Stawarczyk, B; Bähr, N; Beuer, F; Wimmer, T; Eichberger, M; Gernet, W; Jahn, D; Schmidlin, P R (2014). Influence of plasma pretreatment on shear bond strength of self-adhesive resin cements to polyetheretherketone. Clinical Oral Investigations, 18(1):163-170.

Abstract

OBJECTIVES: The aim of this study is to evaluate the adhesion between PEEK and two self-adhesive resin cements after plasma treatment. METHODS: Eight hundred sixty-four polyetheretherketone (PEEK) disks were cut and polished to silicon carbide (SIC) P4000. One half of the specimens were randomly selected and pretreated with plasma, whereas the remaining 432 specimens remained untreated. Subsequently, specimens were randomly allocated to four groups (n = 108/group): Visio.link (Bredent), Signum PEEK Bond (Heraeus Kulzer), Ambarino P60 (Creamed), and a control group without additional treatment. Half of the specimens of each group (n = 54) were then cemented with either RelyX Unicem Automix 2 (3 M ESPE) or with Clearfil SA (Kuraray). All specimens were stored in water for 24 h (37 °C). Afterwards, specimens were divided into three groups (n = 18) for different aging levels: (1) no aging (baseline measurement), (2) thermal aging for 5,000 cycles (5/55 °C), and (3) thermal aging for 10,000 cycles (5/55 °C). Thereafter, shear bond strengths (SBS) were measured, and failure types (adhesive, mixed, and cohesive) were assessed. Data were analyzed using descriptive statistics, four- and one-way ANOVA followed by a post hoc Scheffé test (p < 0.05). RESULTS: No adhesion could be established without adhesive pretreatment, irrespectively, whether plasma was applied or not. Also, no bond strength was measured when Ambarino P60 was applied. In contrast, adhesive pretreatment resulted in SBS ranging between 8 and 15 MPa. No significant differences were found between the resin cements used. In general, no cohesive failures were observed. Groups without plasma treatment combined with Visio.link or Signum PEEK Bond showed predominantly mixed failure types. Control groups, plasma treated, or treated using Ambarino P60 groups fractured predominantly adhesively. CONCLUSION: The use of methyl methacrylate (MMA)-based adhesives allows bonding between PEEK and self-adhesive resin cements. Plasma treatment has no impact on bond to resin cements. CLINICAL SIGNIFICANCE: PEEK reconstructions can be cemented using self-adhesive resin cements combined with pretreatment with MMA-based adhesives.

Abstract

OBJECTIVES: The aim of this study is to evaluate the adhesion between PEEK and two self-adhesive resin cements after plasma treatment. METHODS: Eight hundred sixty-four polyetheretherketone (PEEK) disks were cut and polished to silicon carbide (SIC) P4000. One half of the specimens were randomly selected and pretreated with plasma, whereas the remaining 432 specimens remained untreated. Subsequently, specimens were randomly allocated to four groups (n = 108/group): Visio.link (Bredent), Signum PEEK Bond (Heraeus Kulzer), Ambarino P60 (Creamed), and a control group without additional treatment. Half of the specimens of each group (n = 54) were then cemented with either RelyX Unicem Automix 2 (3 M ESPE) or with Clearfil SA (Kuraray). All specimens were stored in water for 24 h (37 °C). Afterwards, specimens were divided into three groups (n = 18) for different aging levels: (1) no aging (baseline measurement), (2) thermal aging for 5,000 cycles (5/55 °C), and (3) thermal aging for 10,000 cycles (5/55 °C). Thereafter, shear bond strengths (SBS) were measured, and failure types (adhesive, mixed, and cohesive) were assessed. Data were analyzed using descriptive statistics, four- and one-way ANOVA followed by a post hoc Scheffé test (p < 0.05). RESULTS: No adhesion could be established without adhesive pretreatment, irrespectively, whether plasma was applied or not. Also, no bond strength was measured when Ambarino P60 was applied. In contrast, adhesive pretreatment resulted in SBS ranging between 8 and 15 MPa. No significant differences were found between the resin cements used. In general, no cohesive failures were observed. Groups without plasma treatment combined with Visio.link or Signum PEEK Bond showed predominantly mixed failure types. Control groups, plasma treated, or treated using Ambarino P60 groups fractured predominantly adhesively. CONCLUSION: The use of methyl methacrylate (MMA)-based adhesives allows bonding between PEEK and self-adhesive resin cements. Plasma treatment has no impact on bond to resin cements. CLINICAL SIGNIFICANCE: PEEK reconstructions can be cemented using self-adhesive resin cements combined with pretreatment with MMA-based adhesives.

Statistics

Citations

Dimensions.ai Metrics
68 citations in Web of Science®
70 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

371 downloads since deposited on 18 Dec 2013
86 downloads since 12 months
Detailed statistics

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > Center for Dental Medicine > Clinic of Conservative and Preventive Dentistry
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Health Sciences > General Dentistry
Language:English
Date:2014
Deposited On:18 Dec 2013 08:29
Last Modified:06 Oct 2022 12:38
Publisher:Springer
ISSN:1432-6981
OA Status:Green
Publisher DOI:https://doi.org/10.1007/s00784-013-0966-7
PubMed ID:23504226
  • Content: Accepted Version
  • Language: English