Navigation auf zora.uzh.ch

Search

ZORA (Zurich Open Repository and Archive)

Patient-specific finite-element simulation of the human cornea: A clinical validation study on cataract surgery

Studer, H P; Riedwyl, H; Amstutz, C A; Hanson, J V M; Büchler, P (2013). Patient-specific finite-element simulation of the human cornea: A clinical validation study on cataract surgery. Journal of Biomechanics, 46(4):751-758.

Abstract

The planning of refractive surgical interventions is a challenging task. Numerical modeling has been proposed as a solution to support surgical intervention and predict the visual acuity, but validation on patient specific intervention is missing. The purpose of this study was to validate the numerical predictions of the post-operative corneal topography induced by the incisions required for cataract surgery. The corneal topography of 13 patients was assessed preoperatively and postoperatively (1-day and 30-day follow-up) with a Pentacam tomography device. The preoperatively acquired geometric corneal topography - anterior, posterior and pachymetry data - was used to build patient-specific finite element models. For each patient, the effects of the cataract incisions were simulated numerically and the resulting corneal surfaces were compared to the clinical postoperative measurements at one day and at 30-days follow up. Results showed that the model was able to reproduce experimental measurements with an error on the surgically induced sphere of 0.38D one day postoperatively and 0.19D 30 days postoperatively. The standard deviation of the surgically induced cylinder was 0.54D at the first postoperative day and 0.38D 30 days postoperatively. The prediction errors in surface elevation and curvature were below the topography measurement device accuracy of ±5μm and ±0.25D after the 30-day follow-up. The results showed that finite element simulations of corneal biomechanics are able to predict post cataract surgery within topography measurement device accuracy. We can conclude that the numerical simulation can become a valuable tool to plan corneal incisions in cataract surgery and other ophthalmosurgical procedures in order to optimize patients' refractive outcome and visual function.

Additional indexing

Item Type:Journal Article, refereed, original work
Communities & Collections:04 Faculty of Medicine > University Hospital Zurich > Ophthalmology Clinic
Dewey Decimal Classification:610 Medicine & health
Scopus Subject Areas:Life Sciences > Biophysics
Health Sciences > Orthopedics and Sports Medicine
Physical Sciences > Biomedical Engineering
Health Sciences > Rehabilitation
Language:English
Date:2013
Deposited On:27 Feb 2014 09:34
Last Modified:11 Aug 2024 01:49
Publisher:Elsevier
ISSN:0021-9290
OA Status:Closed
Publisher DOI:https://doi.org/10.1016/j.jbiomech.2012.11.018
PubMed ID:23246043

Metadata Export

Statistics

Citations

Dimensions.ai Metrics
38 citations in Web of Science®
43 citations in Scopus®
Google Scholar™

Altmetrics

Downloads

1 download since deposited on 27 Feb 2014
0 downloads since 12 months
Detailed statistics

Authors, Affiliations, Collaborations

Similar Publications